Initial Start-up
When your spa is first actuated, it will go into Priming mode (after displaying some configuration information). The Priming
mode will last for up to 4 minutes and then the spa will begin to heat and maintain the water temperature in the Standard
mode. You can exit Priming mode early by pressing “Warm” or “Cool.”
Temp Set (80°F - 104°F / 26.0°C - 40.0°C)
The last measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is current only when the pump has been running for at least 1
minute.
Warm/Cool
Press the “Warm” or “Cool” button once to display the set temperature. Each time either button is pressed again, the set
temperature will increase or decrease depending on which button is pressed. After three seconds, the LCD will automatically
display the last measured spa temperature.
Mode/Prog
This button is used to switch between Standard, Economy, and Sleep modes. Press “Mode/Prog” to enter mode program-
ming, press “Cool” to cycle through to desired mode (LCD flashes until confirmed), then press “Mode/Prog” to confirm
selection.
Standard mode maintains the desired temperature. The “STANDARD” icon will display until the mode is changed.
Economy mode heats the spa to set temperature only during filter cycles. The “ECONOMY” icon will display until mode is
changed. Pressing “Jets 1” while in Economy mode puts the spa in Standard-In-Economy mode, which operates the same
as Standard Mode, then reverts to Economy Mode automatically after 1 hour. Both the “STANDARD” and “ECONOMY”
icons display in this mode. During this time, a press of the “Mode/Prog” button will revert to Economy Mode immediately.
Sleep mode heats the spa to within 20°F (11°C) of the set temperature only during filter cycles. The “SLEEP” icon will dis-
play until mode is changed.
Standby Mode
Pressing “Warm” or “Cool” then “Jets 2” will turn off all spa functions temporarily. This is helpful when changing a filter.
Pressing any button resets the spa. On some systems the “Jets 1” button will control the pump in Standby Mode (“Drain
Mode”). In this case, press any other button to exit. System will revert to previous mode after 1 hour.
Jets 1
Press the “Jets 1” button once to turn pump 1 on or off, and to shift between low and high speeds if equipped. If left
running, the pump will turn off after a time out period. The pump 1 low speed time out on some systems may be as long as
4 hours. On non-circ systems, the low speed of pump 1 runs when the blower or any other pump is on. It may also activate
for at least 1 minute every 30 minutes to detect the spa temperature (polling) and then to heat to the set temperature if
needed, depending upon mode. When the low speed turns on automatically, it cannot be deactivated from the panel; how-
ever, the high speed may be started.
Jets 2
(optional on some systems) Press the “Jets 2” button once to turn pump 2 on or off, and to shift between low and
high speeds if it is a two-speed pump. If left running, the pump will turn off after a time out period.
Jets 3
(optional on some systems) Press the “Jets 3” button once to turn pump 3 on or off, and to shift between low and
high speeds if it is a two-speed pump. If left running, the pump will turn off after a time out period.
Blower
1-speed operation: on/off; If left on, the blower will automatically turn off after a time out period.
Invert
Press the “Invert” button to change the numbers in the display to read upside down. Press again to return the display to its
normal right-side-up display.
owners stitched 21/1/10 3:40 pm Page 16
Содержание EL
Страница 13: ...GS VS501 11 owners stitched 21 1 10 3 40 pm Page 13 ...
Страница 14: ...Diagnostic Messages 12 THE CANADIAN SPA COMPANY OWNERS MANUAL owners stitched 21 1 10 3 40 pm Page 14 ...
Страница 57: ...Hifestellung 18 Bedienungsanleitung owners stitched 21 1 10 3 41 pm Page 57 ...
Страница 59: ...Notes 20 THE CANADIAN SPA COMPANY OWNERS MANUAL owners stitched 21 1 10 3 41 pm Page 59 ...