Control Functions and 

Applications  

   

Switches and Devices:  

 

MAIN SWITCH  

  

ON Position: 

POWER TO RTC DFC+ & VFD

 

  Activates the VFD and supplies power 

to control circuit 

OFF Position: 

POWER OFF 

  Turns off the power of entire heater

 
HEAT/FAN SWITCH TO FAN 

  

FAN/RIGHT Position:  

FAN ON 

 

  Activates the fan and supplies power to 

control circuit.

 

CENTRE Position: 

TURN FAN OFF 

  Turns off the fan.

 

 

 

HEAT/FAN SWITCH  TO HEAT 

  

HEAT/LEFT Position: 

BURNER ON

  

  Activates the burner circuit & fan.  

CENTRE Position: 

STOP’s the burner and 

cuts off the fan limit opens. 

   

Belimo and RTC Modulating System 

and DFC+ Integrated Gas Fired Heating 
control  

  

This system is made up of 3main components, 

a  variable  gas  valve  or  regulator,  a  discharge 
air  temperature  sensor,  and  an  amplifier 
(DFC+) to control them all.   
  

The discharge air temp sensor is mounted in an 

air mixing tube, located near the discharge air 
side  of  the  heater.  Its  function  is  to  provide 
temperature  information  to  the  amplifier 
(DFC+).  This  information  is  used  by  the 
amplifier to control the “MAX” air temp portion 
of the amplifier.  

  
The  Belimo  or  RTC  Modulating  System 

provides  for  continuous,  steady  heat,  at  the 

rate required. It does not stop the heater at any 
time.  
  

The  modulator  is  the  device  that  does  the 

actual increasing and decreasing of gas flow to 
the  burner.  An  electromagnet  controls  how 
much gas can pass through the modulator. The 
more voltage that is applied to the magnet, the 
more gas that can pass through. The modulator 
is typically full open when a voltage of about 
24-volts  DC  is  applied  from  the  amplifier.                      
Minimum flame results from zero volts DC. 

The 

DF2500  heater  has  a  minimum  BTU  input 
rating  of  553197  BTUs  on  NG  (139403.3 
Kcal)  and  615938

  BTUs  (

155213.8  Kcal)  on 

LP

  The  Belimo  Modulating  System  has  been 
pre-set  at  the  factory  to  insure  this  input.  
No  field  adjustment  of  this  set  point  is 
required.   

 

 

 

Conventional Remote Thermostat  

The  optional  remote  thermostat  (if  used) 

connects  to  the  remote  thermostat  receptacle 
on the heater. The difference is that when this 
device is used, the heater  delivers a constant 
high temperature which is set on the SP of the 
RTC DFC+ Controller, until the set temperature 
on the conventional thermostat is reached. At 
that time, the heater goes to 120

°

F and keeps 

the temperature balanced until the temperature 
at  the  thermostat  falls  below  the  set 
temperature. The heater then goes back to the 
thermostat mode delivers high temperature air.  

To  use  this  device,  select  and  position  the 

thermostat  at  a  location  that  will  represent  a 
good  average  room  temperature  inside  the 
structure to  be  heated that  will  not  be  directly 
affected  by  the  heated  air  discharge  from  the 
heater.  Route  the  plug  end  of  the  cord  to  the 
heater  and  plug  into  the  special  receptacle 
located on the heater control panel.   

T

he thermostat assembly comes with a 50-foot 

cord with a plug, as standard.  

 

The adjustment range is from 40° to 110° F. (5° 

to  43°  C.).  To  use  the  thermostat,  plug  in  the 
remote thermostat to the designated REMOTE 

Содержание ECOBlaze DF2500

Страница 1: ...com pg 1 NG LP DIRECT FIRED SPACE HEATER BLAZE DF2500 WWW CAMPOEQUIPMENT COM REPORT 0367GH009S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CONTROLS...

Страница 2: ...remain with the heater GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRE CAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE...

Страница 3: ...able to any subsequent owner The warranty period is one year from the date of purchase The warranty covers all defects in material and workmanship insofar as they are of Campo Equipment CO LTD manufac...

Страница 4: ...the material flash point Under no circumstance should any combustible material be stored in the airstream within 15 feet 4 57 m of the air discharge port or within 6 15 2cm of the top sides or ends of...

Страница 5: ...ter Use Sherlock 5 second leak of the proper temperature or soapy water on all connections to be sure they are tight Replace or tighten any connection as necessary The supply gas hose being used must...

Страница 6: ...Phase 208 to 240 V supply must be available INSTALLATION Single Phase Three Phase Up to 100 3 6 Up to 100 4 8 Up to 200 3 4 Up to 200 4 6 Up to 300 3 3 Up to 300 4 4 NOTE To power up the heater inside...

Страница 7: ...re is adequate 2 Check to make sure all manual valves are open between the fuel source and the burner 3 Check to make sure the proper voltage is supplied to the heater WARNING A qualified electrician...

Страница 8: ...ndent upon ambient air conditions Excessive pressure build up could occur in the supply line and lead to line failure Consult your local gas supplier for proper piping and gas codes When storing the h...

Страница 9: ...ch gas can pass through the modulator The more voltage that is applied to the magnet the more gas that can pass through The modulator is typically full open when a voltage of about 24 volts DC is appl...

Страница 10: ...f any mixing plates are loose or missing fasteners tighten replace as necessary Always use zinc plated or stainless fasteners 3 Observe flame pattern and if necessary take steps to correct obstructed...

Страница 11: ...The following is the method for testing major electrical components WARNING A qualified electrician should perform all tests replacements and adjustments Testing the Main Switch Before assuming the C...

Страница 12: ...he switch is functioning disconnect and insulate wires leading to the switch N O contacts Connect an ohmmeter or continuity light to the switch N O contacts Place the Heat Fan switch to FAN position T...

Страница 13: ...s power to the VFD Burner does not ignite 1 Voltage insufficient 1 Check incoming supply 2 Electrode disconnected adjusted incorrectly defective 2 Connect adjust replace electrode 3 Air Proving Sw Dis...

Страница 14: ...ctive 4 Replace Air Proving Sw 5 Flame rod dirty defective 5 Clean Replace Flame Rod 6 Inadequate fuel delivery 6 Fill Tank replace regulators valves check gas lines for obstructions TROUBLESHOOTING D...

Страница 15: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 15 WIRING DIAGRAM...

Страница 16: ...89 Digital Panel Mounted Voltmeter C70064 3 POSITION SWITCH C70069 FIXING COLLAR C70067 N O CONTACT BLOCK C80025 VFD C80023 R Fan C90025 Power On Indicator Light GREEN C90029 Outlet for Plug C70052 TI...

Страница 17: ...C82119 2 X21 2 NIPPLE C82120 2 X90 STREET ELBOW C82121 2 X11 2 REDUCER C82122 11 2 X6 NIPPLE C82123 11 2 X90 ELBOW C82124 11 2 X2 NIPPLE C82125 2 UNION C82126 1 4 X11 2 L NIPPLE C80913 1 4 NPT x 1 4...

Страница 18: ...ASSY C82191 PANEL C82192 PANEL C82193 ADAPTER PLATE C82194 R 560 FAN MOUNT ASSY C82195 CORNER STOP C82196 FAN SUPPORT BRACKET C82197 INSULATION BACK PANEL C82087 Serial Number variable data C82088 War...

Страница 19: ...P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 19 C82086 E 560 FAN MOUNT ASSY C82105 15 KVA TRANSFORMER C82106 60A CONTACTORS C50242 AUXILIARY CONTACTS C82042 VSR Relay C60205 Use With...

Отзывы: