STAT receptacle then dial up or down or setting 
it  to  the  desired  room  temperature  to  be 
maintained.    

 

MAINTENANCE 

 

WARNING 

For  your  own  safety,  Lockout  electrical 

power  before  attempting  any  service 
procedures to prevent accidental start-up.

 

 

 

Burner 

  

Proper maintenance of the burner is critical for 

efficient  trouble-free operation.  The burner of 
every Campo heater is tested before shipment, 
however, 

changes 

in 

altitude, 

fuel, 

temperature,  and  humidity  will  affect  the 
performance and efficiency of the burner.  Also, 
the burner should be checked at least annually 
(preferably  before  the  start  of  the  heating 
season) for efficient burning.   
  
1.  Shut 

the 

system 

down 

totally, 

disconnecting or  locking out power supply 
so  there  can  be  no  accidental  start-up 
during inspection.   

  
2.  Inspect  the  burner  carefully,  including 

upstream and downstream sides of mixing 
plates  as  well  as  burner  body  face.    Any 
accumulation of scale or foreign material on 
either  side  of  the  mixing  plates  should  be 
removed with a wire brush.  Check visually 
that  no  holes  in  the  mixing  plates  are 
blocked.    If  any  burner  ports  are  plugged 
(even  partially)  clear  them  with  a  piece  of 
wire or a #47 drill bit (2mm).   

  

WARNING  

Do not enlarge burner ports or performance 

may be drastically affected.

  

  

If  any  mixing  plates  are  loose  or  missing 

fasteners, tighten/replace as necessary.   

Always use zinc plated or stainless fasteners.   

3.  Observe  flame  pattern  and,  if  necessary, 

take steps to correct obstructed ports.  The 
velocity  and  distribution  of  the  air  across 
the  burner  is  pre-set  at  the  factory  and 
should  be  changed  by  authorized  service 
personnel only.   

  

Igniter  

 

 

To  start  ignition,  the  igniter  must  be  adjusted 

properly  and  must  not  be  damaged  or 
defective.    Periodically  the  igniter  should  be 
inspected 

for 

damage, 

corrosion, 

and 

separation.   To  inspect and  adjust the  igniter, 
use the following procedure:  
  
1.  Remove the igniter from the burner.   
  
2.  Visually inspect the igniter for corrosion and 

damage to the insulator and tip.   

  
3.  Consult the Specification Sheet  for proper 

spacing and position.   

  

 

Pressure Regulator  

WARNING

 

 

 

Unqualified  service  personnel  must  not 

make any adjustments on the regulators! 

 

The  pressure  regulator  on  the  manifold 

functions  to  reduce  the  supply  of  gas  to  the 
burner.  There is one pressure regulator on the 
main line.   
  

To  adjust  the  main  line  regulator  pressure, 

remove  the  cap  of  the  regulator;  then  either 
turn  the  adjusting  screw  out  to  decrease 
pressure  or  turn  the  adjusting  screw  in  to 
increase  pressure.  Do  not  make  any 
adjustment  on  the  regulators  without  knowing 
what  you  are  doing  and  having  the  proper 
gauges  attached.    Also,  do  not  bottom  the 
adjusting screw.  
  

The heater is designed to operate with a line 

pressure upstream of the Maxitrol RV91, of 
10  to  14  W.C.  (2.24kPa  to  3.48kPa).      For 
maximum 

efficiency 

and 

safety, 

the 

regulator  must  not  be  adjusted  above  this 

Содержание ECOBlaze DF2500

Страница 1: ...com pg 1 NG LP DIRECT FIRED SPACE HEATER BLAZE DF2500 WWW CAMPOEQUIPMENT COM REPORT 0367GH009S Installation Instructions Manual Maintenance Parts List CAUTION DO NOT TAMPER WITH HEATER OR ITS CONTROLS...

Страница 2: ...remain with the heater GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRE CAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE...

Страница 3: ...able to any subsequent owner The warranty period is one year from the date of purchase The warranty covers all defects in material and workmanship insofar as they are of Campo Equipment CO LTD manufac...

Страница 4: ...the material flash point Under no circumstance should any combustible material be stored in the airstream within 15 feet 4 57 m of the air discharge port or within 6 15 2cm of the top sides or ends of...

Страница 5: ...ter Use Sherlock 5 second leak of the proper temperature or soapy water on all connections to be sure they are tight Replace or tighten any connection as necessary The supply gas hose being used must...

Страница 6: ...Phase 208 to 240 V supply must be available INSTALLATION Single Phase Three Phase Up to 100 3 6 Up to 100 4 8 Up to 200 3 4 Up to 200 4 6 Up to 300 3 3 Up to 300 4 4 NOTE To power up the heater inside...

Страница 7: ...re is adequate 2 Check to make sure all manual valves are open between the fuel source and the burner 3 Check to make sure the proper voltage is supplied to the heater WARNING A qualified electrician...

Страница 8: ...ndent upon ambient air conditions Excessive pressure build up could occur in the supply line and lead to line failure Consult your local gas supplier for proper piping and gas codes When storing the h...

Страница 9: ...ch gas can pass through the modulator The more voltage that is applied to the magnet the more gas that can pass through The modulator is typically full open when a voltage of about 24 volts DC is appl...

Страница 10: ...f any mixing plates are loose or missing fasteners tighten replace as necessary Always use zinc plated or stainless fasteners 3 Observe flame pattern and if necessary take steps to correct obstructed...

Страница 11: ...The following is the method for testing major electrical components WARNING A qualified electrician should perform all tests replacements and adjustments Testing the Main Switch Before assuming the C...

Страница 12: ...he switch is functioning disconnect and insulate wires leading to the switch N O contacts Connect an ohmmeter or continuity light to the switch N O contacts Place the Heat Fan switch to FAN position T...

Страница 13: ...s power to the VFD Burner does not ignite 1 Voltage insufficient 1 Check incoming supply 2 Electrode disconnected adjusted incorrectly defective 2 Connect adjust replace electrode 3 Air Proving Sw Dis...

Страница 14: ...ctive 4 Replace Air Proving Sw 5 Flame rod dirty defective 5 Clean Replace Flame Rod 6 Inadequate fuel delivery 6 Fill Tank replace regulators valves check gas lines for obstructions TROUBLESHOOTING D...

Страница 15: ...CAMPO EQUIPMENT CO LTD ECOBLAZE 6 Carson Court Brampton ON CANADA L6T 4P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 15 WIRING DIAGRAM...

Страница 16: ...89 Digital Panel Mounted Voltmeter C70064 3 POSITION SWITCH C70069 FIXING COLLAR C70067 N O CONTACT BLOCK C80025 VFD C80023 R Fan C90025 Power On Indicator Light GREEN C90029 Outlet for Plug C70052 TI...

Страница 17: ...C82119 2 X21 2 NIPPLE C82120 2 X90 STREET ELBOW C82121 2 X11 2 REDUCER C82122 11 2 X6 NIPPLE C82123 11 2 X90 ELBOW C82124 11 2 X2 NIPPLE C82125 2 UNION C82126 1 4 X11 2 L NIPPLE C80913 1 4 NPT x 1 4...

Страница 18: ...ASSY C82191 PANEL C82192 PANEL C82193 ADAPTER PLATE C82194 R 560 FAN MOUNT ASSY C82195 CORNER STOP C82196 FAN SUPPORT BRACKET C82197 INSULATION BACK PANEL C82087 Serial Number variable data C82088 War...

Страница 19: ...P8 Tel 905 793 2525 Fax 905 793 8768 www campoequipment com pg 19 C82086 E 560 FAN MOUNT ASSY C82105 15 KVA TRANSFORMER C82106 60A CONTACTORS C50242 AUXILIARY CONTACTS C82042 VSR Relay C60205 Use With...

Отзывы: