Appendix C. NL241 Settings
C-13
PakBus Address
This setting specifies the PakBus® address for this device. The value for this
setting must be chosen such that the address of the device will be unique in the
datalogger network. Duplication of PakBus addresses in two or more devices
can lead to failures and unpredictable behavior in the PakBus network. When a
device has a neighbor list or neighbor filter setting filled in for a port, any
device that has an address greater than or equal to 4000 will be allowed to
connect to that device regardless of the neighbor filter.
PakBus/TCP Service Port
This setting specifies the TCP service port for PakBus® communications with
the datalogger. Unless firewall issues exist, this setting probably does not need
to be changed from its default value.
PakBus/TCP Password
Specifies the password that will be used to authenticate any incoming (server)
or outgoing (client) PakBus/TCP sessions. This password is used by the server
to generate a challenge to any client that connects to the PakBus/TCP service
port. If the client fails to respond appropriately, the connection will be
terminated. If this password is blank (the default value), no authentication will
take place.
PakBus/TCP Client Address (1-4)
This setting specifies the IP address of an outgoing PakBus®/TCP client
connection that the NL241 should maintain. If the connection fails, the NL241
will retry that connection periodically until a connection is made. No entry or a
setting of
0.0.0.0
specifies that no client connection will be made.
PakBus/TCP Client Port (1-4)
This setting specifies the TCP port of the outgoing PakBus®/TCP client
connection. Typically, it is not necessary to change this entry from its default
(range 1 to 65535).
PakBus Routes
(read only)
This setting lists the routes that are known to the NL241. Each route known to
the NL241 will be represented by the following four components separated by
commas and enclosed in parentheses. The description of each component
follows:
Port Number
Specifies a numeric code for the port that the router will use. It will
correspond with one of the following:
0
CS I/O
1
RS-232
100 PakBus/TCP Connection — If the value of the port number is
100 or greater, the connection is made through PakBus/TCP.