SECTION 4. SENSOR INSTALLATION
4-4
4.7 LICOR SILICON RADIATION
SENSORS (LI200X, LI200S, LI190SB)
Mount the Radiation Sensor to the LI2003S Base
and Leveling Fixture as shown in Figure 4.7-1.
1. Position the base of the sensor in the
mounting flange on the LI2003S, and
tighten the set screw with the allen wrench
provided. Adjust the three leveling screws
flush with the bottom of the LI2003S.
2. Mount the LI2003S to the 025 or 015
(Section 2.2) using the three mounting
screws provided. Do not tighten the screws
at this time.
3. Level the LI2003S using the bubble level
and leveling screws and tighten the
mounting screws. Remove the red
protective cap prior to use.
FIGURE 4.7-1. LI200X/LI200S/LI190SB and
LI2003S Leveling Fixture
4.8 107/108 TEMPERATURE PROBE
Mount the 107 temperature probe inside the
41301 (UT6P) 6-Plate Gill Radiation Shield as
shown in Figure 4.8-1.
1. Loosen the two mounting clamp screws on
the base of the 41301 (UT6P). Insert the
107 probe through the mounting clamp until
the white heat shrink is even with the
bottom of the clamp.
2. Tighten the two screws evenly until the
clamp is snug against the sensor lead.
FIGURE 4.8-1. 107 Temperature Probe
Bullseye
level
(3) Leveling
Screws
(3) Mounting
Screws
Sensor
015 or 025
Mounting Base
Mounting Clamp
107
UT018
Mounting Clamp
107
41301
UT6P