2. Use the #6 screws and plastic grommets to mount additional peripherals to the enclosure
backplate (see
(p. 8)). Data loggers, power supplies, and most peripherals are
usually attached to the backplate prior to shipment from the factory or are supplied with
additional screws and grommets.
To insert the grommet, push the points of the flanges into the center of any square hole
(see A in
(p. 8). To remove a grommet without damage, remove the enclosure
backplate and use pliers to pinch the grommet flanges together.
NOTE:
Remember to allow space for cables and cable connectors.
3. Route each sensor and peripheral cable through a unique compression fitting (
FIGURE 6-4. Cable inserted into compression fitting
4. Connect sensors and peripherals to the data logger as described in the sensor and
peripheral manuals.
5. Strain relief the sensor wires to the data logger strain relief flanges with the 4-inch cable
ties.
6. Secure sensor and peripheral cables to the side of the enclosure using 8-inch cable ties and
cable tie tabs (see
(p. 9)).
NOTE:
The adhesive of the cable tie tab may not stick during extremely cold temperatures or
extremely high humidity. In these situations, fasten the cable tie tab to the backplate
using a #6 screw and grommet or run the cable tie through two of the enclosure
backplate holes.
Enclosures
11
Содержание ENC 10/12
Страница 1: ...Revision 02 2020 Copyright 2006 2020 Campbell Scientific Inc ...
Страница 24: ...FIGURE 6 12 Tripod leg base LM mounting brackets FIGURE 6 13 Enclosure mount receiver Enclosures 18 ...
Страница 47: ...FIGURE C 5 Exploded view of a CR1000X and AM16 32B mounted on a Stack Mounting Kit Enclosures 41 ...