9. Place two of the desiccant packs from the Enclosure Supply Kit inside of the enclosure.
Reseal the other two inside the plastic bag to use later (see
24)).
10. Remove the backing from the humidity indicator card and attach the card to the right side
of the enclosure.
11. Place a roll of putty around the sensor cables where they enter the enclosure.
12. Press the putty around the cables and into the conduit to form a tight seal.
FIGURE 6-3. An ENC12/14 with one 1.5-inch conduit houses a data logger and BP24
power supply. Door not shown.
6.1.2 Enclosures with individual compression fittings
1. If installing the optional Door-Open Indicator Kit, follow the procedure described in
Enclosures