NOTE:
The mounting holes for the sensor magnet bracket must align with the holes for the
sensor bracket for the door open switch to function properly.
4. Drill small pilot holes for all four mounting holes from the inside of the enclosure.
5. Drill the final holes for the brackets from the outside of the enclosure using a #22 (0.157
inch) drill bit.
NOTE:
Drilling the holes in this manner will prevent the enclosure finish from cracking.
6. From the outside of the enclosure, insert two screws through the newly drilled holes.
7. Place the assembled sensor bracket over the two screws, making sure the sensor is aligned
with the inside edge of the enclosure. Secure the bracket in place with two locknuts.
Enclosures