PS150/CH150 12V Charging Regulators
8
Figure 3-8. Wiring harness plugged into battery connector
3.3
Hook Up Power to Datalogger
Both the PS150 and the CH150 come with a 1 foot black wire attached to one of
the
G
terminal blocks and a 1 foot red wire attached to one of the
12V
terminal
blocks. Attach the red wire from the power supply to the datalogger Power
terminal block marked 12V (Campbell Scientific part number 3768). Attach the
black wire from the power supply to the datalogger Power terminal block marked
“G”.
3.4
Turn On the Charging Source
Turn on the power going to the charging source or uncover the solar panel. The
green “Charge” LED will flash approximately once a second if all incoming
connections are correct and there is an adequate charging voltage present.
3.5
Turn On Power to the Datalogger
Flip the switch on the PS150/CH150 supply to “On”. Verify voltage to the
datalogger with a volt meter, or use a key pad display, or connect to the datalogger
with a laptop or PDA to make sure the datalogger is running correctly.
3.6
LED Indicator
The green “Charge” LED will flash approximately once a second if all incoming
connections are correct and there is an adequate charging voltage present.