PS150/CH150 12V Charging Regulators
6
Connect the secondary power supply leads to the two terminal blocks marked
“CHG”. There is no polarity on the “CHG” terminal blocks, so it does not matter
which wire goes to which “CHG” terminal block, but make sure there is only
ONE wire per block. See Figure 3-5.
Figure 3-5. AC power connections on PS150
3.2
Plug In the Battery
The battery used with the PS150 is shipped inside of the PS150 case if the power
supply is NOT installed inside an enclosure. If the PS150 is mounted inside an
enclosure then the battery will be located separately packed in one of the packing
boxes. This is done to minimize any damage that could occur if the power supply
should get loose from its mounts inside the enclosure during shipment. The
battery will NOT be plugged into the PS150. This is done to minimize
discharging the battery.
To remove the lid from the PS150, pull up on the PS150 lid latch and slide the lid
off as shown in Figure 3-6 and Figure 3-7.
Do not remove the tape holding the battery wiring
harness to the top of the battery! The tape is used to
keep the battery wiring harness out of the way of the
rubber bumpers on the inside of the lid.
WARNING