PS150/CH150 12V Charging Regulators
10
4.2
Battery Packs
Battery
Pack
Model
Amp-Hour
Capacity (Ah)
*Operating
Temperature
Range (ºC)
Battery Family
PS150
7
Charge: –15 to +50
Discharge: –20 to +60
EnerSys/Genesis/YUASA
BP12
12
Charge: –15 to +50
Discharge: -20 to +60
EnerSys/Genesis/YUASA
BP24
24
Charge: –15 to +50
Discharge: –20 to +60
EnerSys/Genesis/YUASA
* Battery specifications shown are from the manufacturer. The PS150/CH150
contains charging algorithms that optimize battery charging over the range of
–40°C to +50°C. Battery usage outside of manufacturer specifications could have
unknown effects on the life of the battery.
Battery life is shortened if the battery is allowed to
discharge below 11.5 V.
4.3
Charging Sources
SP5
SP10
SP30
SP60
SP100
Peak Power
4.5 W
10 W
30 W
60 W
100 W
Voltage @ Peak Power
16.5 V 16.8 V 17.5 V 17.5 V 18.0 V
Current @ Peak Power
0.27 A 0.57 A 1.68 A 3.43 A 5.56 V
Notes:
1.
Specifications assume a 1 kilowatt per square metre illumination and a solar
panel temperature of 25
C (77
F).
2.
Individual panels may vary up to 10%.
3.
The output panel voltage increases as the panel temperature decreases, which
is in the same direction as the recommended VRLA battery charging voltage
change with temperature.
4.
Higher latitudes and less sun hours during winter months might require a
larger panel than what is required to keep the battery charged during the
summer.
WARNING
Содержание CH150
Страница 1: ...PS150 CH150 12 V Charging Regulators Revision 20 6 19 Copyright 2000 2019 Campbell Scientific ...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ......
Страница 10: ...ii ...
Страница 25: ...User Manual 15 Figure 7 2 Installing the A100 Figure 7 3 A100 mounting screw Screw ...
Страница 27: ...User Manual 17 ...