9522B Iridium Satellite Modem and COM9522B Interface Modem
10
This is a summary of the currently active modem profile and ensures that when
power is cycled to the modem it will have the correct auto-answer, DTR, and
flow control settings. Exit Hyperterminal and save your settings for later.
4. Datalogger Configuration
To ensure proper communications with the datalogger, it will be necessary to
configure the datalogger. This can be done via
DevConfig
. Follow the
instructions provided to make a connection to the datalogger.
FIGURE 4-1. Device Configuration Utility
Once connected, select the
ComPorts Settings
tab (FIGURE
4-2
). With the
ComPort
set to
RS-232
, set the
Verify Interval
to its maximum value of
65534
seconds and select the
19.2K Fixed Baud Rate
. If you require the use
of the CS I/O port for communications, select the
CSI/O – ME ComPort
and
set the
Baud Rate
to
19.2K Fixed
. If you require the use of a COM port for
communications, select the appropriate
COMPort
and set the
Baud Rate
to
19.2K Fixed
.
Make any additional changes required for your application. Press the
Apply
button to save the changes.