9522B Iridium Satellite Modem and COM9522B Interface Modem
16
5.1.5 Step 5: PakBusPort Configuration
As shown in FIGURE
5-5
, select the
PakBusPort
. Be sure the
Communications Enabled
box is checked, change the
Maximum Baud Rate
to
19200
(
9600
for a CR10X), set the
Beacon Interval
to
0
, set the
Extra
Response Time
to
15 seconds
, and, if present, set the
Delay Hangup
to
200 ms
.
You may change other settings in this configuration to suit your particular
application. Once complete, move to Step 6 to configure the datalogger.
FIGURE 5-5. PakBus Port Configuration