Installation 4-2
Electrical
Connection
ATTENTION
Execute the hereafter listed operations before connecting the machine to the power
supply.
Preliminary Checks.
Make sure that the mains voltage copes with the voltage quoted on the data plate
located near the cable entry in the back of the machine.
The permissible tolerance on rating is +/- 5%.
Out of this tolerance the proper operation of the functions is no longer guaranteed.
Make sure that there is no moisture in the switch cabinet.
Connecting to the Mains
Connect the machine by means of its own power supply cable (4 x 2.5 mm
2
) with
plug to the EEC prescription.
For the protection of the connection use a circuit breaker, min. breaking capacity
15 kA with min. current 25A for 200 - 254 V ac, 20A for 380 - 440 V ac.
IN CASE OF DAMAGE TO OR REPLACEMENT OF THE
POWER SUPPLY CABLE OR ANY OTHER ELECTRICAL
COMPONENT ANY GUARANTEE AND LAW
RESPONSABILITY IS INVALIDATED.