![Camille Bauer SIRAX BM1450 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/camille-bauer/sirax-bm1450/sirax-bm1450_operating-instructions-manual_487907030.webp)
PM 1001812 000 00
Device handbook SIRAX BM1450
30/36
Table 12: 4X-Adress register
Address
Parameter
Read / write
Start Address Hex
Default values
High Byte
Low Byte
40003
Demand integration time
R/W
00
2
1
40005
Reset parameters (Resetting, see Table 13, page 33)
R/W
00
4
0
40007
RS485 setup code (see Table 14, page 33)
R/W
00
6
4
40009
Mod Address (1...247)
R/W
00
8
1
40027
Nominal voltage (see Table 3, page 14)
R/W
00
1A
48, 110, 1000*
40029
Automatic detection of the nominal voltage
R/WP
00
1C
0
40031
Channel select (e.g. 11111 or 10001, etc.)
R/W
00
1E
11111
40033
Rated nominal current channel 1 (1...2000)
R/W
00
20
5
40035
Rated nominal current channel 2 (1...2000)
R/W
00
22
5
40037
Rated nominal current channel 3 (1...2000)
R/W
00
24
5
40039
Rated nominal current channel 4 (1...2000)
R/W
00
26
5
40041
Current shunt channel 1 (50...150 mV)
R/W
00
28
75
40043
Current shunt channel 2 (50...150 mV)
R/W
00
2A
75
40045
Current shunt channel 3 (50...150 mV)
R/W
00
2C
75
40047
Current shunt channel 4 (50...150 mV)
R/W
00
2E
75
40053
Update rate energy channel 1 (1...60 min)
R/W
00
34
15
40055
Update rate energy channel 2 (1...60 min)
R/W
00
36
15
40057
Update rate energy channel 3 (1...60 min)
R/W
00
38
15
40059
Update rate energy channel 4 (1...60 min)
R/W
00
3A
15
40061
Energy output channel 1 (see table 5, page 15)
R/W
00
3C
2
40063
Energy output channel 2 (see table 5, page 15)
R/W
00
3E
2
40065
Energy output channel 3 (see table 5, page 15)
R/W
00
40
2
40067
Energy output channel 4 (see table 5, page 15)
R/W
00
42
2
40069
Noise current cutoff (0...30)
R/W
00
44
0
40073
Register order
R/Wp
00
48
0
40075
Auto scolling (0=of, 1'065'353'216 = on)
R/W
00
4A
--
40077
Reverse lock channel 1 (see table 4, page 14)**
R/W
00
4C
0
40079
Reverse lock channel 2 (see table 4, page 14)**
R/W
00
4E
0
40081
Reverse lock channel 3 (see table 4, page 14)**
R/W
00
50
0
40083
Reverse lock channel 4 (see table 4, page 14)**
R/W
00
52
0
40085
Reset energy count channel 1 (6, 7 or 8 digits)
R/W
00
54
8
40087
Reset energy count channel 2 (6, 7 or 8 digits)
R/W
00
56
8
40089
Reset energy count channel 3 (6, 7 or 8 digits)
R/W
00
58
8
40091
Reset energy count channel 4 (6, 7 or 8 digits)
R/W
00
5A
8
40093
Factory reset
R/W
00
5C
0
40095
Password
R/W
00
5E
0
40097
Serial-No.
R/WP
00
60
--
40099
Model-No.
R/WP
00
62
600/6002
40101
Firmware version No.
R/WP
00
64
--
40103
User assignable screen ON/OFF (0=off, 1=on)
R/W
00
66
0
40105
User screen 1 (see Table 2, page 11)
R/W
00
68
1
40107
User screen 2 (see Table 2, page 11)
R/W
00
6A
2
40109
User screen 3 (see Table 2, page 11)
R/W
00
6C
3
40111
User screen 4 (see Table 2, page 11)
R/W
00
6E
6
40113
User screen 5 (see Table 2, page 11)
R/W
00
70
7