PM 1001812 000 00
Device handbook SIRAX BM1450
12/36
5. Setup screen
display mode Measur
ement
codE ----
(P
asswor
d)
codE xxxx ----
codE xxxx
(P
asswor
d input)
codE xxxx xxxx
(confirm)
SEL S
YS P
ArA
(S
yst
em par
amet
er)
Quit (End)
Aut
o-dE
t no/yes
(Aut
o voltage
det
ection)
chAN SEL ch-1234
xxxx
(Channel selection)
U-FS xxxx V
(Nominal voltage)
A-FS (1-4)
xxxx
(Curr
ent full scale)
A-SH (1-4)
xxx
(Curr
ent shunt setting)
dit xx
(Int
egr
ation time)
Enr
t (1-4) xx
(Ener
gy r
at
e)
rEV L
oc (1-4) x
(Reverse locking)
Aut
o-Sc
no/yes
(Aut
o scr
olling)
nC xx
(Noise curr
ent)
EnOP (1-4)
x
(Ener
gy unit)
Edr
c (1-4) x
(Reset digit ener
gy count)
OK
OK
OK
OK
OK
OK
SEL SEr P
ArA
(Comm. par
amet
er)
Quit
(End)
Quit
(End)
Quit
(End)
Quit
(End)
dEV
-Addr xxx
(Device addr
ess
setting)
OK
OK
OK
OK
SEL rSE
t P
ArA
(P
ramet
er r
eset)
SEL Out P
ArA
(output par
amet
ers
SEL uSEr ScrEEn
(User scr
eens)
restar
t
scr
een
Model scr
een
version scr
een
SEL rEL
Y Out
(Relay output)
SEL rEL
Y-x Out
(Relay selection)
type=LiMit?
SEL rESE
t
none:
(none
)
ALL:
(all)
on-hr:
(On hour)
intr:
(No of int
erruption)
hi-
V:
(V
oltage hi)
Lo-
V:
(V
oltage lo)
hi-A (1-4):
(Curr
ent hi)
Lo-A (1-4):
(Curr
ent lo)
EnEr (1-4):
(Ener
gy)
dMd (1-4):
(Demand)
A-hr (1-4):
(Amper
e hour)
r-hr (1-4):
(Run hour)
CgAN (1-4):
(select
ed channel data)
PAritY xxxx
(P
arity selection)
bA
Ud-r
t
xxxx
(Baud r
at
e)
OK
OK
OK
OK
OK
OK
SEt
PuL
-dur
(pulse dur
ation)
uSEr Scr
xx
(User scr
een)
OK
FA
Ct rESE
t
(F
act
or
y r
eset)
ConFirM
xxx
(No, Y
es
)
(F
act
or
y r
eset)
Scr no zz xx
(Scr
een selection)
tYPE
xxxxxxx
nonE, LiMit, P
uLSE*,
tiMEr
, rEMotE, rEVL
oc,
rtc rL
Y
(Relay selection)
PuL
-dur
60, 100, 200
(pulse dur
ation selection)
PArA-SEL
xx
(Limit par
amet
er select)
ConF xxxx
(Relay configur
ation)
Ye
s
Ye
s
Ye
s
No
type=P
uLSE?
PArA-SEL
xx
(P
ulse output)
PuL/diV xxxx
(P
ulse r
at
e)
Ye
s
triP
-Pt
xxx
(Trip point)
HYS
t
xx.x
(Hyst
er
esis setting)
En-dL
Y
xxxx
(On-delay setting)
dE-dL
Y
xxxx
(Off-delay setting)
Ye
s
No
type=tiMEr?
Ye
s
No
type=rEMotE?
CZC xxxx
(No of cycles)
ConF xxxx
(T
imer configur
ation)
Ye
s
On
-d
LY
xxx
(On-delay setting)
Off
-d
LY
xxxx
(Off-delay setting)
OK
OK
Passwor
d valid
OK
OK
Passwor
d invalid
push long
C
A
A
B
B
B
D
C
Quit
(End)
OK
D
C
Ye
s
No
No
Ye
s
no
type=rEV L
oc?
type=nonE
uSEr Scr
=0?
PArA/SEL xxxxxxxx
(Reverse locking par
am.)
ConF xxxx
(Relay configur
ation)
Ye
s
No
On
-d
LY
xxx
(On-delay setting)
Off
-d
LY
xxxx
(Off-delay setting)
Quit
(End)
OK
D
C
Quit
(End)
OK
D
C
Quit
(End)
OK
D
Quit
(End)
Quit
(End)
Quit
(End)
C
C