background image

CONTROL PANEL 

FOR 24 V GEARMOTORS

ZL22N 

INSTALLATION MANUAL

EN English

FA00993-EN

Содержание ZL22N

Страница 1: ...CONTROL PANEL FOR 24 V GEARMOTORS ZL22N INSTALLATION MANUAL EN English FA00993 EN...

Страница 2: ...e operator with direct jets of water sprinklers water cleaners etc Make sure the anchoring spot is clear of any potential impacts that the anchoring surfaces are solid and that elements suitable for t...

Страница 3: ...sers Fit in plain sight the machine s ID plate when the installation is complete If the power supply cable is damaged it must be immediately replaced by the manufacturer or by an authorized technical...

Страница 4: ...use The ZL22N control panel was designed for controlling 24 V UNIPARK parking saver barriers Any installation and or use other than that specified in this manual is forbidden Technical data Type ZL22N...

Страница 5: ...ing 6 Button for programming 7 Terminal board for connecting the accessories 8 Terminal board for connecting the gearmotor 9 Terminal board for connecting control and safety devices 10 Terminal board...

Страница 6: ...x 1 5 mm 2 2G x 2 5 mm 2 TX Photocells 2 x 0 5 mm 2 RX photocells 4 x 0 5 mm 2 Accessories 2 x 0 5 mm 2 Command and control devices 2 x 0 5 mm 2 When operating at 230 V and outdoors use H05RN F type...

Страница 7: ...e to rotate Assemble the pressure hinges Fit the hinges into the box either on the right or left and fasten them using the supplied screws and washers Snap the cover onto the hinges Close it and secur...

Страница 8: ...e original instructions Input voltage 1 Power supply cable with double insulation 230 V AC 50 60 Hz 2 Accessories 24 V AC max 25 W power supply output 3 Control board power supply input Radio control...

Страница 9: ...onds from mode 1 to mode 2 the red LED flashes twice from mode 2 to mode 1 the red LED flashes once Each time the board is switched on if it is in mode 1 the red LED remains off if it is in mode 2 the...

Страница 10: ...RX TX RX TX Page 10 Manual FA00993 EN 12 2018 CAME S p A Translation of the original instructions if not used Safety devices Photocells Input for photocells or magnetic loop Reopening during closing W...

Страница 11: ...993 EN 12 2018 CAME S p A Translation of the original instructions The motor current consumption is proportional to the parking saver power Amperometric sensor sensitivity adjustment Sensitivity DIP s...

Страница 12: ...tor Before fitting the AF board you MUST CUT OFF THE MAIN POWER SUPPLY and remove any emergency batteries Adding a user If one or more LM22N boards are connected to the control panel it is not possibl...

Страница 13: ...gth flashes about 4 seconds and quick flashes about 2 seconds until it it switches off Reset DIP switch 4 to OFF Deleting a single user Set DIP switch 4 to ON Keep pressed the PROG button on the contr...

Страница 14: ...ld be disposed of as solid household waste and simply separated from other waste for recycling Whereas other components control boards batteries transmitters and so on may contain hazardous pollutants...

Страница 15: ...Page 15 Manual FA00993 EN 12 2018 CAME S p A Translation of the original instructions...

Страница 16: ...CAME S p A Via Martiri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA00993 PL 12 2018 CAME S p A Translation of the original instructions...