Power supply
Power supply to the
230V AC 50/60 Hz
control panel
Terminals for powering accessories:
- at 24 V (AC) powered with 230 V (AC)
- at 24 V (AC) powered with 24 V (AC)
Overall allowed power: 40 W
Electro lock connection (12V-15 W max.) with
EMEGA
9
Lighting and warning devices
Movement Flasher (contact rated for:
24V AC - 25W Max.) - Flashes
while gate opens and closes.
Jumper in posiotion A
- Cycle lamp Contact rated for: 24
V - 25 W Max.
) :
- It lights up the driveway and stays on from the
moment the gate leaves start opening until they are
fully closed (including the automatic closing time). If
automatic closing is not activated, the lamp stays on
only during movement.
Jumper 12
page 3
"Gate open" warning light Contact rated for: 24 V - 3 W Max.
)- Warns
of open gate position, turns off when gate is closed.