background image

15

3

2

4

5

6

1

10

14

11

12

7

8

9

13

RA

R

R C

F A

F

M

N

M N R

ADT x ZL170

16

17

P.

 

33

  

- M

an

u

al

 c

od

e  

31

9

U

3

4

 

31

9

U

3

4

 

 ve

r.

 

1.

0

1.

0

 0

9

/2

0

11 © C

A

M

E c

an

ce

lli

 a

u

to

m

ati

ci

 s

.p.

a.

  - T

h

e d

ata a

n

d i

n

fo

rm

ati

on

 in

 th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e w

ith n

o o

b

lig

ati

on

 to n

otify s

ai

d c

h

an

g

es

ENGLISHENGLISH

ENGLISH

4.1 Dimensions, centre distances and anchoring holes

4.2 Main components

(mm)

1. Transformer  
2.  Amperometric sensitity during travel 

adjustment trimmer 

3.  Amperometric sensitity during deceleration 

adjustment trimmer 

4.  Opening / closing strike zone adjustment 

trimmer

5.  Automatic closing adjustement trimmer 

6.  Code memorising button 
7.  Terminals for connecting to the 

LB18 battery charger (see p. 9) 

8.  630mA-F control unit fuse 
9.  3.15F accessories fuse 
10. Radio code notifi cation LED light 
11. Functions selector 
12. Output selector jumper B1-B2/cycle lamp 

13. 3.15A-F line fuse 
14. Radio frequency card socket
15. Connection terminals
16. ADT card for managing 

decelerations (see pages 5-6) 

17. ADT terminals (use only with Frog 

24V, see p. 6) 

BLACK

BLUE

BROWN

RED

WHITE

BL

UE

PURPLE

 

Содержание Z 24 Series ZL170N

Страница 1: ...SERIES Z 24 CONTROL PANEL FOR 24V GEARMOTORS INSTALLATION MANUAL ZL170N English EN 319U34EN ...

Страница 2: ...g command pre flashing movement indicator obstacle detections when gate is not moving at any point opening recoil The available command modes are opening closing opening closing with maintained action open only with radio command total stop The photocells after detecting an obstacle may trigger the reopening of the closing gate a partial stop if gate is moving a total stop The control panel featur...

Страница 3: ...justment trimmer 3 Amperometric sensitity during deceleration adjustment trimmer 4 Opening closing strike zone adjustment trimmer 5 Automatic closing adjustement trimmer 6 Code memorising button 7 Terminals for connecting to the LB18 battery charger see p 9 8 630mA F control unit fuse 9 3 15F accessories fuse 10 Radio code notification LED light 11 Functions selector 12 Output selector jumper B1 B2...

Страница 4: ...parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage Make sure you have all the tools and materials needed to carry out the installation in total safety and in accordance with current regulations Here are some examples Secure the base of the panel in a safe area we suggest using bolts with max diametre of 6 mm Philips rounded heads Per...

Страница 5: ...o notify said changes ENGLISH ENGLISH ENGLISH 6 Electrical connections Gearmotor FERNI and EMEGA The ADT card should be fastened to the gearmotor terminals as shown and connected to the control panel on terminals M N and R the RA terminal is not active on the FERNI and EMEGA models FROG Gearmotor Whereas with Frog ADT card and terminals after connecting to the cables coming out of the gearmotor th...

Страница 6: ...40 W Electro lock connection 12V 15 W max with EMEGA9 Lighting and warning devices Movement Flasher contact rated for 24V AC 25W Max Flashes while gate opens and closes Jumper in posiotion A Cycle lamp Contact rated for 24 V 25 W Max It lights up the driveway and stays on from the moment the gate leaves start opening until they are fully closed including the automatic closing time If automatic clo...

Страница 7: ...iusura Input for safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend Shortcircuit 2 and C1 if unused C1 N C contact di riapertura durante la chiusura C3 N C partial stop contact Input for safety devices like photocells sensitive edges and other devices tha...

Страница 8: ...e E881 electro lock 6 1 Configuring the LB18 terminals If using the LB18 battery recharger card remove all bridges and connect the card as shown in the accompanying literature Factory configuration To power the E881 lock with 24V on terminals 11 S which are normally at 12V do the following to the bridges fig A WITH the LB18 card leave only one bridge on B D and connect the card as shown in the acc...

Страница 9: ...e activated open stop close stop button or radio command 3 ON Operating the activated open only radio command 4 ON Preflashing duringt opening and closing activated 5 ON Obstacle detection activated 6 ON Maintained action activated operation excludes the radio command function 7 ON Ramming function activated for easier lock releasing 8 OFF Partial stop activated with safety device connected to term...

Страница 10: ...s as shown in fig 1 it should be adjusted on either the opening or closing strike plate Activate the gate with a command button or with the transmitter and turn the OP TIME TL trimmer clockwise until the gate leaf inverts its direction of travel the moment it touches the obstacle template Then turn the template from the short side fig 2 and check that the gate leaf stops by touching the obstacle tem...

Страница 11: ...or that is triggered when an obstacle blocks its movement when opening or closing It normally inverts the direction of travel but if it is triggered when the gate is 5 cm from the closing strike plate or oepning stop it completely stops the gate movement see also adjusting the OP TIME trimmer on p 11 The device s sensitivity is adjustable via trimmers p 10 Warning If an obstacle is detected twice ...

Страница 12: ...cancelli automatici s p a The data and information in this manual may be changed at any time with no obligation to notify said changes ENGLISH 10 Activating the radio command Connect antenna cable to the apposite terminals Antenna Trasmettitori see instruction sheet in the packaging of the AF43SR radi frequency card see instructions on box Jumper in position B Radio receiver s second channel outpu...

Страница 13: ...tify said changes ENGLISH ENGLISH ENGLISH Only for the AF43S radio frequency cards position jumper as shown depending on the series of transmitters you are using AF card Plug in the radio frequency card onto the electronic board AFTER CUTTING OFF THE MAIN POWER SUPPLY or disconnecting the emergency batteries N B The electronic card recognises the radio frequency card only when it is powered up Fre...

Страница 14: ... CAME cancelli automatici s p a The data and information in this manual may be changed at any time with no obligation to notify said changes ENGLISH 2 The transmitter button sends the code and the LED will stay on to signal that memorisation was succesful Keep button pressed CH1 on the electronic card the LED notification light flashes Memorise the code onto the card as follows Flashing LED AF rad...

Страница 15: ... plastic iron electric cables are solid urban waste These can be disposed of at local solid waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially authorised disposal firms Before proceeding it is always a good idea to check your local legislation on the matter ...

Страница 16: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 122nd St Medley Medley FL 33178 1 305 433 3307 1 305 396 3331 ASIA CAME Asia Pacific CAME Asia Pacific 60 Alexandra Terrace 09 09 Block C The ComTech 118 502 Singapore Singapore 65 6275 0249 65 ...

Отзывы: