8.4 Opening/closing and develeration speeds
To adjust the travel and deceleration speeds, shift the fastons to the spefically shown transformer connectors.
Deceleration adjusting faston
min/max
Gate travel speed adjusting faston:
min/max
9 Amperometric Sensor
The control panel featrure an
amperometric motor sensor
that is triggered when an obstacle blocks its movement when opening
or closing.
It normally inverts the direction of travel, but if it is triggered when the gate is 5 cm from the closing strike plate or oepning stop,
it completely stops the gate movement (see also adjusting the OP TIME trimmer on p. 11).
The device's sensitivity is adjustable via trimmers (p. 10).
Warning!
If an obstacle is detected twice consecutively while closing (and with the Automatic Closing function activated), the
operator will respond in the following way:
1) by inverting the movement, and fully opening the gate;
2) by deactivating the Automatic Closing;
3) by blocking any of the control panel functions;
To reactivate the operator you must issue a command using the transmitter or the buttons connected on 2-3 and 2-7.