p.
22
- M
an
u
al
FA
0
1
0
5
4
-E
N
- 0
1/
2
0
18 - © C
A
M
E S
.p.
A
. -
Tr
ansla
tio
n of t
he o
riginal inst
ru
ct
io
ns
Automatic closing after either partial or pedestrian opening
By default, the feature is disabled.
To enable it:
Select the DIP-switches as shown and press the PROG key on the control board. THE PRG LED stays lit
and the buzzer sounds off for 1 second.
To return to the default setting, press the PROG key again. The LED blinks and the buzzer sounds off 2
times.
⚠
The automatic closing time is permanently set to 10 seconds.
Pre-flashing (pre-flashing duration: 5 s)
By default, the feature is disabled.
To enable it:
select the DIP switches as shown and press the PROG key on the control board. The PRG LED stays on
and the buzzer sounds off for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Closing thrust
By default, the feature is disabled.
To enable it:
select the DIP switches as shown and press the PROG key on the control board. The PRG LED stays on and
the buzzer sounds off for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Saving the trimmer value
Use the trimmers to set the automatic closing time (A.C.T.), the opening and closing latching points, the
second motor's closing-delay speed, the slow-down speed (SDS) and the sensitivity (SENS.).
To save the values:
select the DIP switches as shown and press the PROG button on the control board. The PRG LED stays on
and the buzzer sounds off for 1 second.
Services test
By default, the feature is disabled.
To enable it:
Select the DIP switches as shown and press the PROG key on the control board. The LED stays on and
the buzzer sounds for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
Button-activated maintained action
By default, the feature is disabled.
To enable it:
select the DIP-switches as shown and press the PROG key on the control board. The LED stays on and
the buzzer sounds for 1 second.
To return to the default setting, press PROG again. The LED blinks and the buzzer sounds off 2 times
⚠
The gate opens and closes when the button is kept pressed.
Opening button connected on 2-3P (contact NO) and closing button connected on 2-7 (contact NO)
All other control devices, even radio-based ones, are excluded.
Содержание OPB001CB
Страница 2: ...1 2 3 1 2 3 ...
Страница 31: ...Pag 31 Manuale FA01054 IT 01 2018 CAME S p A istruzioni originali ...
Страница 33: ...Swing gate operator OPB001CB INSTALLATION MANUAL EN English FA01054 EN ...
Страница 34: ...1 2 3 1 2 3 ...
Страница 63: ...p 31 Manual FA01054 EN 01 2018 CAME S p A Translation of the original instructions ...
Страница 65: ...Automatisme pour portails battants OPB001CB MANUEL D INSTALLATION FR Français FA01054 FR ...
Страница 66: ...1 2 3 1 2 3 ...
Страница 95: ...Page 31 Manuel FA01054 FR 01 2018 CAME S p A Traduction des instructions originales ...
Страница 97: ...Автоматика для распашных ворот OPB001CB РУКОВОДСТВО ПО УСТАНОВКЕ RU Русский FA01054 RU ...
Страница 98: ...1 2 3 1 2 3 ...
Страница 127: ...Стр 31 Руководство FA01054 RU 01 2018 CAME S p A Перевод оригинальных инструкций ...