background image

Page 

28

 - Manual 

FA01626-EN

  - 02/2023 - © C

AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T

ranslation of the o

riginal instructions

Parameter reset

Restore factory settings except for the functions: [Radio decoding], [Boom length] and the settings related to travel calibration.

A4

Parameter reset

0 =Deactivated (Default)
1 = Activated

Manoeuvre counter

View the number of manoeuvres performed by the operator (1 = 1000 manoeuvres).

A5

Manoeuvre counter

1 = 1000 maneuvers

FW version

Display the firmware version number.

H1

FW version

Import/export data

1

 Insert the MEMORY ROLL card into the corresponding connector on the control 

board.

2

 Press the “Enter” button to access programming.

3

 Use the arrows to choose the desired function.

-F50
Save user data, timings and configurations to the memory device (memory roll or 
USB key).
-F51
Upload user data, timings and configurations from the memory device (memory roll 
or USB key).

 The functions are displayed only when a MEMORY ROLL card is inserted.

 Before inserting and removing the MEMORY ROLL card, DISCONNECT THE 

MAINS POWER SUPPLY TO THE LINE.

 Remove the MEMORY ROLL card after the data has been loaded.

Содержание GARD G3250

Страница 1: ...Automatic road barriers G3250 G3250X G3250A INSTALLATION MANUAL FA01626 EN EN English...

Страница 2: ...m is no longer intact as the result of an accident or installation error In these cases the tensioned springs no longer guarantee that the boom is balanced The boom may suddenly rotate when being rele...

Страница 3: ...th the installation rules It should completely cut off the power supply according to category III surcharge conditions Demarcate the entire site properly to prevent unauthorised personnel from enterin...

Страница 4: ...uidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Before dismantling and disposing of the produc...

Страница 5: ...lvanized steel designed to fit accessories Intended use Ideal solution for apartment blocks and industrial use Any installation and or use other than that specified in this manual is forbidden Usage l...

Страница 6: ...of the original instructions Description of parts Barrier 1 Anti shearing cover 2 Boom attachment 3 Boom anchoring plate 4 Lock for release 5 Inspection hatch 6 Microswitch support plate 7 Mechanical...

Страница 7: ...nnecting the transponder selector switch 5 Display 6 Accessories fuse 7 Control board fuse 8 Terminal board for connecting the transformer 9 Terminal board for connecting the transformer thermal cut o...

Страница 8: ...o connect the antenna use RG58 cable up to 5 m For installation in an outdoor environment use cables with properties at least equivalent to those of type H05RN F with designation 60245 IEC 57 For inst...

Страница 9: ...lly fastened in place Preliminary operations If the flooring does not allow the device to be fastened in a solid and stable way lay a cement slab Dig a hole for the foundation frame Set up the corruga...

Страница 10: ...nged at any time and without notice Translation of the original instructions Fill the hole with soil around the concrete block Remove the nuts from the screws Insert the electrical cables into the tub...

Страница 11: ...ice Translation of the original instructions Changing the boom opening direction The barrier is set up for installation on the left If the boom has already been assembled lift it up to a vertical posi...

Страница 12: ...Lock the gearmotor and fit the mechanical stops on the opposite end Fit the boom anchoring plate again using threadlocker on the screws Fit the microswitch support plate and reattach the spring Invert...

Страница 13: ...symbol one every metre 2 Insert the rope light into the grooves on both sides of the boom 3 Fit the insulating cap to one end of the rope light 4 Thread the power supply cable through the hole in the...

Страница 14: ...es to the same size as the boom slot minus 10 millimetres 2 Insert the slot cover profiles into the grooves on both sides of the boom 3 Insert the anti impact rubber profile into the groove 4 Cut off...

Страница 15: ...boom 1 Release the gearmotor 2 Loosen the clamping nut on the rod 3 Manually turn the spring to increase or reduce the traction The boom should stabilise at 45 4 Fasten the locknut Position the boom v...

Страница 16: ...with mechanical limit switches Check that the boom is parallel to the road surface when it is in the closed position and at about 89 when it is in the open position Correct the boom s horizontal posi...

Страница 17: ...time and without notice Translation of the original instructions Correct the boom s vertical position Release the gearmotor Open the inspection hatch 1 Turn the mechanical stop until you reach the des...

Страница 18: ...ocedures Before working on the control panel disconnect the mains power supply and remove the batteries if any Connecting to the electrical network F Line fuse L Phase N Neutral Earth F Power supply o...

Страница 19: ...ng 2 Control device NO contact OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control device NO contact PARTIAL OPENING function The c...

Страница 20: ...and closes 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY CX 1 3 Safety devices Connect the safety devices to the CX and or CY inputs During programming configure the type of action that must be performed by th...

Страница 21: ...nction F60 Sleep Mode DIR DELTA S photocells Standard connection Multiple photocell pairs can be connected Connection with safety test Multiple photocell pairs can be connected See function F5 Safety...

Страница 22: ...be connected DXR DLX photocells Connection with safety test Multiple photocell pairs can be connected See function F5 Safety devices test RX TX 10 11 OUT 10 11 SY 10 11 E1 E6 Rx Tx 1 2 3 3P 4 5 7 CY...

Страница 23: ...t manoeuvre is always to open the gate Wait for the manoeuvre to be completed Press the ESC button or STOP button immediately in the event of any faults malfunctions strange noises or vibrations or un...

Страница 24: ...Open warning light Barrier status warning Device connected to the 10 5 output F10 Open warning light 0 Warning light on default The light stays on when the boom is moving or open 1 Warning light flash...

Страница 25: ...e during opening and closing F22 Operating time 5 to 120 seconds default 20 seconds Courtesy time Set the lighting device operation time F25 Courtesy time 60 to 180 seconds Default 180 seconds Opening...

Страница 26: ...ry roll or USB key F51 Read data 0 Deactivated Default 1 Activated Transferring MASTER SLAVE parameters Enable the sharing of parameters programmed on the Master barrier with the Slave barrier This on...

Страница 27: ...mmand opens the Master barrier Choose the function to be assigned to the user Press ENTER to confirm You will be asked to enter your user code Send the code from the control device Repeat the procedur...

Страница 28: ...neuvers FW version Display the firmware version number H1 FW version Import export data 1 Insert the MEMORY ROLL card into the corresponding connector on the control board 2 Press the Enter button to...

Страница 29: ...RSE connector Connect up the electrics for the devices and accessories For information on connecting the electrics for the devices and accessories please see the ELECTRICAL CONNECTIONS section The dev...

Страница 30: ...ON The first barrier opens the vehicle passes the first barrier closes the second barrier opens the vehicle passes and the second barrier closes Electrical connections Connect the two electronic board...

Страница 31: ...ction F49 Press ENTER to confirm Select 2 Select function F52 Select 1 Saving users All save user operations must be performed only on the control board set as the MASTER For user storage operations s...

Страница 32: ...t installation manual For information on choosing products and accessories please see our product catalogue If the barrier with an articulated joint is used check that the moving parts of the joint ar...

Отзывы: