p.
5
- M
an
u
al
c
od
e:
F
A
0
0
6
8
8
-E
N
FA
0
0
6
8
8
-E
N
v.
0
6
/2
0
17
- © C
am
e S
.p.
A
. T
h
e c
onte
nts of th
is
m
an
u
al
m
ay b
e c
h
an
g
ed at a
ny ti
m
e w
ith
ou
t p
rio
r n
oti
ce
.
GENERAL INSTRUCTIONS FOR INSTALLING
⚠
Only skilled, qualified staff must install this product.
Important! Using original CAME control and safety devices and accessories ensures easy installation and system maintenance.
Preliminary checks
⚠
Before beginning, do the following:
• make sure the plate is anchored to a solid spot;
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules. It should
completely cut off the power supply according to category III surcharge conditions (that is, with minimum contact openings of 3 mm);
• Make sure that any connections inside the casing (ones that ensure continuity to the protection circuit) are fitted with additional insulation
with respect to those of other electrical parts inside;
• set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any mechanical damage.
Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable regulations. The figure
shows some of the equipment installers will need.
Connection
Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power supply 230 V AC
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm2
3G x 2.5 mm2
3G x 4 mm2
Flashing light
2 x 0.5 mm2
-
-
Photocell transmitters
2 x 0.5 mm2
Photocell receivers
4 x 0.5 mm2
Command and safety device
2 x 0.5 mm2
Antenna
RG58
max 10 m
Metal mass detector
(see product literature)
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected
devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. If connecting products that are not contemplated in this manual, see the literature accompanying said products
Cable types and minimum thicknesses
Содержание G4040Z
Страница 25: ...Installation manual G4040Z G4040IZ AUTOMATIC BARRIERS FA00688 EN English EN...
Страница 49: ...Manuel d installation G4040Z G4040IZ BARRI RES AUTOMATIQUES FA00688 FR Fran ais FR...
Страница 73: ...G4040Z G4040IZ FA00688 RU RU...
Страница 74: ...2 FA00688 RU FA00688 RU 1 06 2017 Came S p A CAME S P A 2 5 20 1 8 1 5 EN12453 EN12445 8...
Страница 78: ...5 0 0 3 4 0 400 r 40 6 FA00688 RU FA00688 RU 1 06 2017 Came S p A 24...
Страница 79: ...1 N M PT F FC FA 4 2 3 7 FA00688 RU FA00688 RU 1 06 2017 Came S p A 600 90 M N FA FC...
Страница 80: ...G03756 G03750 8 FA00688 RU FA00688 RU 1 06 2017 Came S p A UNI5931 M8x20 G03750 G03756...
Страница 83: ...45 4 5 4 5 11 11 FA00688 RU FA00688 RU 1 06 2017 Came S p A 45...
Страница 85: ...04 COM NC NC COM 13 13 FA00688 RU FA00688 RU 1 06 2017 Came S p A 24 3 24 32 dip 9 ON 2 3 2 4 DIP 2 24...
Страница 86: ...RX TX RX TX 14 14 FA00688 RU FA00688 RU 1 1 06 2017 Came S p A DIR DELTA S DELTA C1 C5 C1 2 1 C5 DIP 8 ON 89...
Страница 87: ...1 15 15 FA00688 RU FA00688 RU 1 06 2017 Came S p A...
Страница 91: ...4 19 19 FA00688 RU FA00688 RU 1 06 2017 Came S p A...
Страница 94: ...22 22 FA00688 RU FA00688 RU 1 06 2017 Came S p A 6...