ALTERNATE CONNECTION
Important! First do the following on both operators:
- insert the RSE card (with the dipswitches set to OFF) on the panel connector on both operators.
- connect the two boards with a CAT 5 cable (max. 1,000 m) to terminals A-A / B-B / GND-GND; see CONNECTION FOR PAIRED OR ALTERNATE
OPERATION)
Connect the safety and control devices with the OPEN function (contact
2-3
) and STEP-BY-STEP (contact
2-7
) on the panel on the MASTER operator.
Connect the safety and control devices with the PARTIAL/PEDESTRIAN OPENING function (contact
2-3P
) on the panel of the SLAVE operator only.
Important! Activate the F 19 function (automatic closing time) on the panel on both operators.
Saving
Follow the procedure for entering a user with the OPEN and STEP-BY-STEP command on the MASTER panel and the PARTIAL/PEDESTRIAN OPENING
on the SLAVE panel.
Confi guring the MASTER operator
Select function F 49. Press ENTER to confi rm.
Select 2 (alternate) and press ENTER.
Parameter transfer from MASTER to SLAVE
Select function F 52 on the MASTER panel.
Select 1 and press ENTER.
Programming
Set the following functions on both barriers:
- motor type (A1);
- motor test (A2);
- total stop (F1);
- travel calibration (A3).
Proceed with setting and adjusting the MASTER panel.
Function modes
OPEN command (contact 2-3). To open the MASTER barrier boom.
PARTIAL/PEDESTRIAN OPENING command (contact 2-3P). To open the SLAVE barrier boom.
STEP-BY-STEP command (contact 2-7). Both booms open. This is an emergency opening command to free up the passage.
For information on the types of command that can be selected and associated with users, see the section ENTERING USERS WITH AN ASSOCIATED
COMMAND.
Approach the MASTER barrier which will
open automatically only after the SLAVE
barrier has closed automatically.
Send a STEP-BY-STEP command (contact
2-7) from the transmitter or other control
device to open the MASTER and SLAVE
barrier booms at the same time.
Approach the SLAVE barrier which will
open automatically only after the MASTER
barrier has closed automatically.
Send an OPEN command (contact 2-3)
from the transmitter or other control device
to open the MASTER barrier boom.
Send a PARTIAL/PEDESTRIAN OPENING
command (contact 2-3P) from the
transmitter or other control device to open
the SLAVE barrier boom.
Содержание G4040E
Страница 33: ...AUTOMATIC BARRIERS FA00132 EN English EN INSTALLATION AND OPERATION G4040E G4040IE...
Страница 65: ...MANUEL D INSTALLATION G4040E G4040IE BARRI RES AUTOMATIQUES FA00132 FR Fran ais FR...
Страница 97: ...G4040E G4040IE FA00132 RU RU...
Страница 98: ...2 FA00132 RU 3 04 2017 CAME S p A CAME S P A 2 5 20 1 8 1 5 EN 12453 EN12445 8...
Страница 102: ...5 0 0 3 4 0 400 r 40 6 FA00132 RU 3 04 2017 CAME S p A 24...
Страница 103: ...1 N M 4 2 3 7 FA00132 RU 3 04 2017 CAME S p A 90 M N 600...
Страница 104: ...UNI5931 M8x20 G03756 G03750 8 FA00132 RU 3 04 2017 CAME S p A G03750 G03756...
Страница 105: ...UNI5931 M8x12 UNI5931 M8x20 L 1 3 4 2 UNI6954 2 9x13 UNI6954 3 9x19 9 FA00132 RU 3 04 2017 CAME S p A...
Страница 107: ...45 4 5 4 5 11 FA00132 RU 3 04 2017 CAME S p A 45...
Страница 113: ...1 8 9 1 8 9 17 FA00132 RU 3 04 2017 CAME S p A 89...
Страница 114: ...F i F i F 2 F 3 0 i 0 3 i 3 S1 GND 18 FA00132 RU 3 04 2017 CAME S p A ENTER 1 ENTER 10 ESC ENTER ENTER ESC ENTER...
Страница 119: ...ESC ENTER a 3 ESC ENTER i ESC ENTER c l i ESC ENTER o p I 23 FA00132 RU 3 04 2017 CAME S p A 1 3 ENTER 2 1 ENTER 3 4...
Страница 121: ...10 11 1 E 10 11 1 E ZL 38 4 25 FA00132 RU 3 04 2017 CAME S p A...
Страница 125: ...29 FA00132 RU 3 04 2017 CAME S p A 6...
Страница 127: ...31 FA00132 RU 3 04 2017 CAME S p A CAME S p A UNI EN ISO 14001...