background image

CAME

CAME 

 France

France 

 S.a.  

S.a.  

FRANCE

7, Rue Des Haras

Z.i. Des Hautes Patures

92737 Nanterre Cedex

Nanterre Cedex

 (+33) 0 825 825 874

 (+33) 1 46 13 05 00

GERMANY 

CAME Gmbh Seefeld

 

CAME Gmbh Seefeld

Akazienstrasse, 9

16356  Seefeld 

Seefeld Bei Berlin

 (+49) 33 3988390

 (+49) 33 39883985

CAME Automatismes S.a. 

CAME Automatismes S.a. 

FRANCE

3, Rue Odette Jasse

13015 Marseille

Marseille

 (+33) 0 825 825 874

 (+33) 4 91 60 69 05

U.A.E. 

CAME Gulf Fze

 

CAME Gulf Fze

Offi ce No: S10122a2o210

P.O. Box 262853 

Jebel Ali Free Zone - Dubai 

Dubai 

 (+971) 4 8860046

 (+971) 4 8860048

CAME Automatismos S.a. 

CAME Automatismos S.a. 

SPAIN

C/juan De Mariana, N. 17-local

28045 Madrid

 Madrid

 (+34) 91 52 85 009

 (+34) 91 46 85 442

RUSSIA 

CAME Rus

 CAME 

Rus

Umc Rus Llc

Umc Rus Llc

Ul. Otradnaya D. 2b, Str. 2, offi ce 219 

127273, Moscow

Moscow 

 (+7) 495 739 00 69

 (+7) 495 739 00 69 (ext. 226)

CAME United Kingdom Ltd. 

CAME United Kingdom Ltd. 

GREAT BRITAIN

Unit 3 Orchard Business Park

Town Street, Sandiacre

Nottingham 

Nottingham - Ng10  5bp

 (+44) 115 9210430

 (+44) 115 9210431

PORTUGAL 

CAME Portugal 

 CAME 

Portugal 

Ucj Portugal Unipessoal Lda

Ucj Portugal Unipessoal Lda

R

ua Liebig, nº 23 

2830-141 Barreiro

Barreiro  

 (+351) 21 207 39 67

 (+351) 21 207 39 65

CAME Group Benelux S.a. 

CAME Group Benelux S.a. 

BELGIUM

Zoning Ouest 7

7860 Lessines

 Lessines

 (+32) 68 333014

 (+32) 68 338019

INDIA 

CAME India 

 CAME 

India 

Automation Solutions Pvt. Ltd

Automation Solutions Pvt. Ltd

A - 10, Green Park 

110016 - New Delhi

New Delhi  

 (+91) 11 64640255/256

 (+91) 2678 3510

CAME Americas Automation Llc 

CAME Americas Automation Llc 

U.S.A

11345 NW 122nd St. 

Medley

Medley, FL 33178 

 (+1) 305 433 3307

 (+1) 305 396 3331

ASIA 

CAME Asia Pacific 

 CAME 

Asia 

Pacific 

60 Alexandra Terrace #09-09

B

lock C, The ComTech

118 502 Singapore

Singapore  

 (+65) 6275 8426

 (+65) 6275 5451

CAME Gmbh 

CAME Gmbh 

GERMANY

Kornwestheimer Str. 37

70825 Korntal 

 Korntal Munchingen Bei Stuttgart 

 (+49) 71 5037830

 (+49) 71 50378383

CAME Cancelli Automatici S.p.a. 

CAME Cancelli Automatici S.p.a. 

ITALY

Via Martiri Della Libertà, 15

31030 Dosson Di Casier 

 Dosson Di Casier (Tv)

 (+39) 0422 4940 

 (+39) 0422 4941

Informazioni Commerciali 800 848095

ITALY 

CAME Sud s.r.l.

CAME Sud s.r.l.

Via F. Imparato, 198

Centro Mercato 2, Lotto A/7 

80146 Napoli

 Napoli

 (+39) 081 7524455

 (+39) 081 7529190

CAME Service Italia S.r.l. 

CAME Service Italia S.r.l. 

ITALY

Via Della Pace, 28

31030 Dosson Di Casier 

 Dosson Di Casier (Tv)

 (+39) 0422 383532 

 (+39) 0422 490044

Assistenza Tecnica 800 295830

Assistenza Tecnica 800 295830

ITALY 

CAME Global Utilities s.r.l.

CAME Global Utilities s.r.l.

V

ia E. Fermi, 31

20060 Gessate

Gessate

 (Mi)

 (+39) 02 95380366

 (+39) 02 95380224

01_2011

www.came.com

www.came.it

E

n

g

li

s

h

E

n

g

li

s

h

 - M

a

n

u

a

l c

o

d

1

1

9

G

V

6

5

11

9

G

V

6

5

 v

e

r.

 2

.1

2

.1

  0

2

/2

0

11 © C

A

M

E

 C

a

n

ce

lli A

u

to

m

a

ti

ci

 S

.p.

a

T

h

e d

a

ta a

n

d i

n

fo

rm

ati

o

n i

n

 t

h

is

 m

a

n

u

a

l m

ay b

e c

h

a

n

g

e

d at a

n

y time a

n

d wit

h

o

u

t o

b

lig

a

ti

o

n

 o

n

 t

h

e p

a

rt

 of C

a

me C

a

n

ce

lli A

u

to

m

a

ti

ci

 S

.p.

a

. to n

o

tif

y s

a

id

 c

h

a

n

g

e

s.

Содержание G3000

Страница 1: ...G3000 G3000I SERIES GARD INSTALLATION MANUAL QUICK ROAD BARRIERS English EN...

Страница 2: ...l release of the barrier arm p 11 Description of the control panel p 12 Technical data p 12 Main component parts p 12 Electrical connections p 13 Gearmotor encoder and transformer only for possible ma...

Страница 3: ...ible to the public All maintained action com mands must be placed where the moving gate leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the pos...

Страница 4: ...d reflective adhesive strips 001G03002 60 mm white varnished aluminium tube arm L 3 m complete with red reflective adhesive bands 001G02040 40 mm balancing spring for the 001G03002 barrier 001G04060 5...

Страница 5: ...eflective adhesive strips 2 Semi eliptical arm attachment flange complete with flange cover and arm end caps 3 60 mm tube arm attachment flange complete with flange cover and arm end caps 4 40 Balanci...

Страница 6: ...ctric cable raceways making sure these are protected from any mechanical damage Set up a drainage tube to prevent stagnation of moisture that can lead to oxydation Check that any connections inside th...

Страница 7: ...same line i e sequential ones the dimensions shown on the table must be reconsidered according to the total draw and actual distances When connecting products not featured in this manual only refer t...

Страница 8: ...must be perfectly level clean and with the bolt threading completely on the surface Wait at least 24 hrs for everything to solidify Remove the nuts and washers from the threaded screws The following...

Страница 9: ...g mounting phase the barrier may be unstable Do not rest against barrier until fully mounted to avoid any tumbling over LEFT hand barrier RIGHT hand barrier Installing the cabinet NOTE This manual sho...

Страница 10: ...se the inspection hatch and power up the system Activate the arm to check whether it is parallel to the road surface when close and at about 89 when open To correct the vertical position opening lower...

Страница 11: ...s broken or cracked during an accident etc the tension springs no longer provide balan ce This may result in sudden rotating movements of arm attachment and or of the arm itself Insert the key into th...

Страница 12: ...nd button or transmitter key All connections are protected by quick fuses see table The card handles the following functions automatic closing after an opening command FUSE TABLE to protect fuses for...

Страница 13: ...Terminals for powering accessories 24 A 230 V AC Overall allowed power 40 W Power source and accessories Power supply 230 V AC Frequency 50 60 Hz N B remove the protection which is fastened with one...

Страница 14: ...in case of Maintai ned Action Flashing light for open barrier arm Contact rated for 24 V 3 W Max Warns that the barrier arm is open See function settings on F 10 Flashing light dome and luminous cord...

Страница 15: ...the test on Electrical connection to work the photocells safety test Safety devices Con gure the CX or CY contact N C which is an input for EN 12978 regulation compliant safety devices such as photoc...

Страница 16: ...NTER button pressed for at least a full second Use the arrows to choose the menu item you wish then press ENTER use the arrows also the move in the sub menus Use the arrows to increase or decrease the...

Страница 17: ...sitivity during movement F 35 Sensitivity during deceleration F 37 Adjusting the opening deceleration beginning point of the M1 motor F 38 Adjusting the closing deceleration beginning point of the M1...

Страница 18: ...the buttons or transmitter to resume movement Insert safety device on 1 C2 if unused select function 0 0 0 Deactivated 1 Activated by default F 2 CX input NC safety contact with ppssobility to associ...

Страница 19: ...p close stop modes 0 step step by default 1 sequential F 9 Obstacle detection when motor is idle the arm is down up or after a total stop command it prevent movement if the safety davices i e photocel...

Страница 20: ...fore the arm begins to travel the pre flashing time can be deactivated or adjusted from 1 to 10 0 Deactivated by default 1 1 second 2 2 seconds 10 10 seconds F 22 Working time working time of the moto...

Страница 21: ...percentage of the arm s complete travel 40 40 of the arm travel 50 50 of the arm travel by default 70 70 of the arm travel F 38 Motor closing deceleration point adjusts the motor s beginning point of...

Страница 22: ...iated command adding user max 25 users associated to a command via tramsitter 1 1 step command open close 2 2 sequential commande open stop close stop 3 open only command U 2 Cancelling user cancellin...

Страница 23: ...e arrow buttons to select the command 1 step 2 sequential 3 open to assign to the user Press ENTER to confirm Adding user with associated command 3 an available number between 1 and 25 will flash for...

Страница 24: ...1 CAME Cancelli Automatici S p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes ENGLISH...

Страница 25: ...perly and that motor runs properly Er3 encoder out of order call for assistance Er4 services test error check proper connections and functioning state of the safety devices Er5 insufficient working ti...

Страница 26: ...ger high voltage Transit forbidden during operation Important general safety instructions The periodic maintenance actionsto be done by the end users are cleaning the photocells glass checking the pro...

Страница 27: ...____________________________________________________________________________________________ _______________________________________________________________________________________________ Extraordina...

Страница 28: ...be handed over the specially authorised disposal firms Before proceeding it is always a good idea to check your local legislation on the matter DO NOT DISPOSE OF IN NATURE Troubleshooting Dismantling...

Страница 29: ...5 ver 2 1 2 1 02 2011 CAME Cancelli Automatici S p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify s...

Страница 30: ...Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 122n...

Отзывы: