PMP Synchronization Solutions User Guide
Installing the CMM5
PMP-0297 007v001 (January, 2017)
2-46
Installing a Split DC Power Line
A split DC power line is used in situations where you have one injector and one controller.
Procedure 4 Installing a Split DC Power Line
1
Ensure that the following hardware is available:
•
(1) 240 Watt Power Supply
•
(1) DC Line Filter
•
(1) Junction Box
•
(1) Connector (Injector)
•
(1) Connector (Controller)
•
(2) Wire Nuts
•
(1) AC Lline Adapter
2
Connect the Red and Black leads of the 240 Watt Power Supply to the Line side of the D
Line Filter.
3
Connect the Red and Black leads of the Load side of the DC Line Filter to junction box.
4
Connect the Injector and Controller leads to the other side of the junction box.
Figure 22: Installing a Split DC Power Line