PMP Synchronization Solutions User Guide
CMM5 Controller Configuration
PMP-0297 007v001 (January, 2017)
2-33
Update Injector Firmware
Perform the following steps to update Injector firmware:
Procedure 5 Update Injector Firmware
1
Create a directory on the PC and copy over the firmware (*.hex) and TeraTerm
macro (*.ttl) files.
2
Bring up a TeraTerm terminal window and establish communication with the CMM5
serial port.
3
From the TeraTerm window, run the macro from the Control -> Macro menu.
4
A file selection dialog box will open. Select the macro that was copied over and run
it.
5
Another dialog box will open, from which the firmware file to be uploaded is
selected.
6
The macro will automatically write the contents of the firmware to the CMM5, which
boots on the new image. The previous module configuration is carried over
unchanged.
7
If the upgrade fails, the CMM5 module will display an error message and will come
up in the bootloader state. In this case disconnect all cables except the USB
connection and rerun the macro