PMP Synchronization Solutions User Guide
UGPS installation and operation
PMP-0297 007v001 (January, 2017)
4-16
UGPS installation and operation
Observe the following guidelines when installing a UGPS module:
•
The unit may be pole mounted or surface mounted (on a horizontal surface with an
unobstructed view of the sky).
•
The UGPS should NOT be installed as the highest object at the site.
•
Orient the GPS antenna so that it has clear access to the southern horizon (if installed north of
the equator) or clear access to the northern horizon (if installed south of the equator).
•
Note locations of 600SS surge suppressors when installing the UGPS unit. Reference
diagrams. Compatible power supplies for the UGPS are listed in
•
Observe cable length specifications in
•
Cambium Networks recommends using shielded Category 5E cables for outdoor installations.
•
The UGPS Power over Ethernet pinout (External Power Port) differs from IEEE Standard
803.3af, and the two should not be intermixed. The UGPS Power over Ethernet pinout is the
same as Cambium Networks FSK broadband radios.
Table 27 Compatible 30V Power Supplies and Cords
Model
Description
N000900L001A
Gigabit Ethernet-Capable Power Supply
N000900L007A
Cable, UL PSU Cord Set, US
N000900L008A
Cable, UL PSU Cord Set, EU
N000900L009A
Cable, UL PSU Cord Set, UK
N000900L010A
Cable, UL PSU Cord Set, Brazil