PMP 450 Configuration and User Guide
Task 5: Configuring security
pmp-0050 (May 2012)
2-69
Attribute
Meaning
Select Key
This option allows operators to choose which authentication key is used:
Use Key above
means that the key specified in
Authentication Key
is used
for authentication
Use Default Key
means that a default key (based off of the SM‘s MAC
address) will be used for authentication
Encryption
Specify the type of airlink security to apply to this AP:
Encryption Disabled
provides no encryption on the air link. This is the
default mode.
Encryption Enabled
provides encryption, using a factory-programmed
secret key that is unique for each module.
Encrypt Downlink Broadcast
When
Encryption Enabled
is selected in the
Airlink Security
parameter
(described above) and
Enable
is selected in the
Encrypt Downlink
Broadcast
parameter, the AP encrypts downlink broadcast packets as
DES where the AP is DES capable.
AES where the AP is AES capable.
SM Display of AP Evaluation
Data
You can use this field to suppress the display of data about this AP on the
AP Evaluation tab of the Tools page in all SMs that register.
Web, Telnet, FTP Session
Timeout
Enter the expiry in seconds for remote management sessions via HTTP,
telnet, or ftp access to the AP.
IP Access Control
You can permit access to the AP from any IP address (
IP Access Filtering
Disabled
) or limit it to access from only one, two, or three IP addresses
that you specify (
IP Access Filtering Enabled
). If you select
IP Access
Filtering Enabled
, then you must populate at least one of the three
Allowed Source IP
parameters or have no access permitted from any IP
address, including access and management by Prizm.
Allowed Source IP
1 to 3
If you selected
IP Access Filtering Enabled
for the
IP Access Control
parameter, then you must populate at least one of the three
Allowed
Source IP
parameters or have no access permitted to the AP from any IP
address. You may populate as many as all three.
If you selected
IP Access Filtering Disabled
for the
IP Access Control
parameter, then no entries in this parameter are read, and access from all
IP addresses is permitted.