6.2
MOUNTING VARIANTS
Fix Point SUPPORT
/
LINEAR SUPPORT
When set up with fix point support, the modules only touch the substructure via the clamps. When
set up with linear support, however, the modules sit on top of the substructure. Thus, for a linear
support, place a silicone-free rubber support between the substructure and the clamps so that the
glass and metal do not touch at any point.
THE FOLLOWING MOUNTING VARIANTS ARE POSSIBLE:
•
Substructure lateral beneath the module with two clamps per module side (figure 7)
•
Substructure diagonal beneath the longer sides with two clamps per module side (figure 8)
Germany/Europe: Use approved clamps included on the Calyxo contact list (PAS-11-05-0166-EN)
exclusively.
USA / Canada: Refer to PAS-11-05-0190EN when installing a UL 1703 compliant system.
Figure 7
A= ≥70 mm
B= 275 mm ±25 mm
2
1= Module
2= Junction box
3= Module clamp
1
4= Substructure
Figure 8
A= ≥70 mm
B= 275 mm ±25 mm
1= Module
2= Junction box
3= Module clamp
4= Substructure