IMPORTANT SAFETY INSTRUCTIONS 

This manual contains important safety instructions for the PV module that must be 

followed during the maintenance of PV modules. 

To reduce the risk of electric shock, do not perform any servicing unless you are 

qualified to do so. 
1.

 

The installation must be performed by a certified installer /servicer to ensure 
system integrity and safety. 

2.

 

The  installation  is  only  allowed  after  referring  and  understanding  of 
GENERAL 

INSRUCTONS 

and 

INSTALLATION 

MANUAL 

-

PHOTOVOLTAIC MODULES-. If you don’t have your personal copy, please 
contact  your  installer  or  local  Sharp  office  listed  in  Sharp  Solar  web  site  : 
URL : 

http://www.sharp-world.com/solar

 

          

http://www.sharp.eu

 

3.

 

Do not pull the PV cables. 

4.

 

Do not touch any surface of module. 

5.

 

Do not place/drop objects onto the PV modules. 

6.

 

Do not disassemble or attempt to repair the PV module by yourself. 

7.

 

Do not drop the PV module. 

8.

 

Do not damage, pull, bend, or place heavy material on cables. 

9.

 

Upon  completion  of  any  service  or  repairs,  ask  the  installer/servicer  to 
perform  routine  checks  to  determine  that  the  PV  modules  are  in  safe  and 
proper operating condition. 

 
10.

 

When  replacement  parts  are  required,  be  sure  the  installer/servicer  uses 
parts specified by the manufacturer with same characteristics as the original 
parts. Unauthorized substitutions may result in fire, electric shock, or other 
hazard. 

11.

 

Consult your local building and safety department for required permits and 
applicable regulations. 

12.

 

In  regions  with  snow,  the  module  can  sustain  a  snow  load  of  up  to  50cm 
(20in) (when the module is mounted in the portrait orientation / short frame 
side  facing  down)  or  100cm(39in)  (when  the  module  is  mounted  in  the 
landscape orientation / long frame side facing down). 

13.

 

As a result of sliding snow, the mechanical load increases when the number 
of module rows in the matrix of a PV installation increases. When mounting 
the module in the portrait orientation for more than 3 rows, the accumulated 
snow load may cause the lower edge of the module frame to deform. Take 
necessary measures (e.g. snow stopper) to avoid possible damage. 

14.

 

Periodically  remove  any  overhanging  snow  and/or  ice  from  the  module 
framework as it may cause deformation of the module frame. 

 
 
 

 
 

GENERAL INSTRUCTIONS 

 

1. INTRODUCTION 

Thank  you  for  choosing  SHARP  photovoltaic  (PV)  module.

 

This  Installation  Manual  contains  essential  information  for  the  electrical  and  mechanical 

installation that you must know before installing SHARP PV modules. This also contains safety information you need to be familiar with. All the information 
described in this manual are the intellectual property of SHARP and based on the technologies and experiences that have been acquired and accumulated 
in the long history of SHARP. This document does not constitute a guaranty, expressed or implied. SHARP does not assume responsibility and expressly 
disclaims liability for loss, damage, or expense arising out of or in any way connected with installation, operation, use or maintenance of the PV modules. No 
responsibility is assumed by SHARP for any infringement of patents or other rights of third parties that may result from use of PV module. SHARP reserves 
the right to make changes to the product, specifications or installation manual without prior notice. 

 

2. COMPONENTS  

 

 
 

*this image can be applicable for all models regardless number of cells 

 
 
 

3. GENERAL INFORMATION 

 (INCLUDING WARNING AND SAFETY) 

The installation of PV modules requires a great degree of skill and should 

only  be  performed  by  a  qualified  licensed  professional,  including  licensed 
contractors  and  licensed  electricians.  Please  be  aware  that  there  is  a 
serious  risk  of  various  types  of  injury  occurring  during  the  installation 
including  the  risk  of  electric  shock.  All  SHARP  PV  modules  are  equipped 
with  a  permanently  attached  junction  box  that  will  accept  variety  of  wiring 
applications  or  with  a  special  cable  assembly  for  ease  of  installation,  and 
they do not require special assembly. 
 

GENERAL WARNING 

1.

 

PV modules are heavy. Handle with care. 

2.

 

Before  you  attempt  to  install,  wire,  operate  and  maintain  the  PV 
module,  please  make  sure  that  you  completely  understand  the 
information described in this installation manual. 

3.

 

Contact with electrically active parts of a PV module such as terminals 
can result in burns, sparks and lethal shock whether the PV modules 
are connected or not. 

MODEL 

NU-SA /SC*** series, 
ND-RB*** series     

CAUTION: HIGH VOLTAGE 

To reduce the risk of electric shock, do not touch. 

Содержание NU-SA Series

Страница 1: ...se the lower edge of the module frame to deform Take necessary measures e g snow stopper to avoid possible damage 14 Periodically remove any overhanging snow and or ice from the module framework as it may cause deformation of the module frame GENERAL INSTRUCTIONS 1 INTRODUCTION Thank you for choosing SHARP photovoltaic PV module This Installation Manual contains essential information for the elect...

Страница 2: ...ent for US market only 16 When installing PV modules in a readily accessible location the National Electrical Code NEC 690 33 requires installing the additional locking sleeve Multi Contact part PV SSH4 on the connector Note that this sleeve is not included with the module This requirement is for circuits operating in excess of 30 volts nominal maximum system voltage for DC or 30 volts for AC circ...

Страница 3: ...igure 1 when connecting the modules to a battery or to other modules If not connected correctly the bypass diode s could be destroyed Maximum series configuration please refer to Table 1 This value is calculated under the condition of Voc at 40 C Maximum parallel configuration Parallel connection of each string shall be conducted with following two options Any other parallel connections are prohib...

Страница 4: ...re mounted on should be rigid SHARP PV modules are designed to ensure optimal electrical performance under the condition that they are mounted on rigid support structures Deformation of support structure may damage PV module with its electric performance When mounting the module on structure ensure that no corner has a displacement of more than 2mm 0 08in per every 1000mm 39 37in of the diagonal f...

Страница 5: ... fuse sizes and size of controls connected to the module output for US market Refer to Sec 690 8 of the National Electric Code for an additional multiplying factor of 125 percent 80 percent de rating which may be applicable Application Class This module is rated as Application class A according to IEC61730 Application class A means General access hazardous voltage hazardous power applications Modu...

Отзывы: