SECTION 11: FLOWSENSE
®
(-FL)
making
since 1986
water work
SECTION 12: (-F) OPTION:
All models of Calsense controllers that have a (-F)
option can use up to three (3) separate Points of
connection.
12A. Point of Connection 1 (POC 1)
1.
Press the
MAIN MENU
key.
The MAIN MENU screen is displayed (Figure 12.1).
Setup Status
Flow Radio Remote
Weather Reports
CALSENSE WATER MANAGEMENT SYSTEM
Programs & Stations Lights
Figure 12.1
2.
Press the
FLOW
Menu key.
The FLOW METER, MASTER VALVE & PUMP
screen is displayed (Figure12.2).
.
Pump On-at-a-Time
Track Estimated Mainline Capacity
FLOW METER, MASTER VALVE & PUMP
POC (MV & FM)
Figure 12.2
3.
Press the
POC (MV & FM)
Menu key.
The POINT OF CONNECTION screen is displayed
(Figure 12.3).
Point of Connection: POC 1
Master valve is NORMALLY CLOSED
POINT OF CONNECTION (MV & FM)
Flow Meter in use? NO
(This POC always used with irrigation)
Figure 12.3
Note:
POC 1 is set for use with irrigation always
and cannot be changed.
4.
Press the blue
ARROW
key to
highlight MASTER VALVE IS setting.
5.
Press the
PLUS
or
MINUS
keys to
change the MASTER VALVE IS
setting.
The Master Valve default setting is for a normally
closed Master Valve. There are two (2) settings,
•
NORMALLY CLOSED:
A normally closed
Master Valve is in the closed position until
voltage is applied to open it.
•
NORMALLY OPEN:
A normally open
Master Valve is in the open position until
voltage is applied to close it.
Note:
Be sure to select the correct type of Master
Valve installed, if it is incorrect the Master Valve will
close whenever a station is irrigated and no water
will flow when a valve is turned on.
If using a FMBX flow meter see:
1.
FMBX flow meter setup
If using a regular flow meter see:
2.
Regular flow meter setup
If using a combination of FMBX along with regular
style flow meters you will have to select “USE YOUR
OWN K & OFFSET NUMBERS” for all three flow
meter entries.
12A.1 FMBX flow meter setup
If the flow meter installed on the system is a
Calsense FMBX, change the “Use your own K &
Offset” to YES, (The screen will appear as shown in
Figure 12.4).
Point of Connection: POC 1
Flow Meter in use ? YES
Use your own K & Offset? YES
( This POC always used with irrigation )
K: 10.000 OFFSET: 0.200
POINT OF CONNECTION (MV & FM)
Master Valve is NORMALLY CLOSED
Figure 12.4