![Calsense ET2000 Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/calsense/et2000/et2000_programming-manual_485271021.webp)
21
DIAGNOSTICS
08/28
04:23PM
Sta 3 Time 10.0 to 12.0
08/28
04:22PM
Sta 5 Time 15.0 to 17.0
08/28
04:20PM
Sta 12 Time 15.0 to 18.0
08/26
01:33PM
CHANGE : NO Water Days
08/26
11:18AM
Resumed - TEST OVER
08/26
11:18AM
STOP KEY PUSHED
08/26
11:01AM
Paused due to TEST
07/28
08:33AM
CHANGE : PROG A Water Days
07/28
08:30AM
CHANGE : PROG B Water Days
07/22
10:32PM
NO CURRENT for Stn 3
07/22
10:11PM
NO CURRENT for Stn 12
06/28
07:38AM
Program Restart
06/28
06:02AM
Power Fail
Diagnostics (shown above) keeps a record of all program changes made to the controller and all alerts generated by the controller.
Press the
PLUS
or
MINUS
Key to scroll up or down to view all the data contained at the Diagnostics screen.
Irrigation Details
Clear Station
IRRIGATION DETAILS
STN
HOLD-OVER
TO IRRIG
STATUS
Clear Hold-Over
2
0.0
8.5
Irrigating
3
8.3
5.0
Soaking
4
0.0
10.0
Waiting
5
0.0
10.0
Waiting
6
0.0
0 . 0
7
(station not in use)
8
(station not in use)
1
0.0
10.0
Waiting
STATION ORDER
Turn-on order of Stations during
scheduled irrigation
(shown in order they turned on)
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
2
1
3
4
5
6
7
11
10
9
12
8
2
1
3
4
5
6
7
11
10
9
12
8
Irrigation Details (shown above) will report every station’s current status. In the example above, stations 1 through 5 are currently
in an irrigation cycle, station 6 is inactive and stations 7 and 8 are not being used (they have been turned off at the Station In Use
screen). Station 2 is irrigating and has 8.5 minutes left to irrigate. Station 3 has completed an irrigation cycle and is in a soak-in
cycle, it also has 8.3 minutes of hold-over time. Stations 1, 4 and 5 are waiting to start their first irrigation cycle.
You can use the Irrigation Detail screen to view the current status of any station, you can also clear a station from it’s current
irrigation cycle, test cycle or manual cycle, by Pressing the
PLUS
or
MINUS
Key until the desired station is highlighted, then
Press the
CLEAR STATION
Menu Key, the station will be cleared and the next station will begin. You can also clear a station’s
hold-over time by Pressing the
PLUS
or
MINUS
Key until the desired station is highlighted, then Press the
CLEAR HOLD-OVER
Menu Key.
Station Order
The ET2000 does not necessarily irrigate in sequence, and sometimes it might be necessary to know the order in which the
stations on the controller irrigated. You can view the order in which each station irrigated at the Station Order screen. Starting in
the lower right corner of the screen and working back you will see the order from last station to irrigate to the first station to
irrigate. In the example above the last station to irrigate was station 8 (lower right), the next to last station to irrigate was station 12
then 9, 10, 11, 7 etc. The first station to irrigate was station 2.
Diagnostics