
ENG
9. INSTA L L ATION ON THE WA L L
E n s u re that the appliance is correctly positioned in the right direction, with the control dials
in the top right-hand corn e r.
Installing and connecting the appliance.
■
Your appliance must be installed vert i c a l l y, in the direction shown in diagram n° 2.
■
Connect your appliance to a fixed vertical unit (with the control box on the right-hand side of
the appliance) and in accordance with applicable re g u l a t i o n s .
■
B e f o re installing your appliance, unscrew the wall bracket located on the back of the appliance.
■
Use appropriate means of installation ( wall plugs) to install the wall bracket (G) on the
w a l l .
■
S e c u re the wall bracket (G) to the wall, at the re q u i red location, respecting the prescribed mini-
mum distances in relation to the floor, walls, etc. (Fig. 2)
In compliance with norms, you must not fit a power plug onto this lead.
When connecting, the lead must be cut, in order to keep no more than the length re q u i red for
c o n n e c t i o n . If you are in any doubt consult a qualified electrician. A two-pole circ u i t - b re a k e r
must be installed in your home’s electrical installation. The circ u i t - b reaker must have a 3 mm
contact gap.
■
Hook the appliance in place according to the drawing.
■
Note the 2 hooking slots located on the back of your appliance :
- place the appliance against the wall, with the upper slot above the wall bracket,
- slide your appliance downwards until it hooks into the 2 upper and lower attachments,
- lock in place using the screw (F) supplied with the installation kit (fig. 3).
■
If necessary, seek advice from a specialist.
This position enables you to automatically maintain the temperature above 5°C in a
n o rmally insulated room, with a volume of less than 30 m
3
, when the outer temperature is
g reater than - 10°C.
- Tu rn the thermostat dial A to position .
- Tu rn dial B to position
●
: on.
8. FROST PROTECTION SETTING
Your appliance is equipped with an ambient thermostat A which maintains the chosen tem-
p e r a t u re at a constant level in the room you wish to heat. The maximum position enables
c o n t inuous operation of the appliance in normal conditions of use. The intermediate positions
c o rrespond to the diff e rent temperature settings and automatically stop and re s t a rt the appliance.
- Position 9 : hotter.
- Position 1 : cooler.
As soon as the re q u i red ambient temperature is reached, the appliance stops and re s t a rts auto-
matically to maintain this temperature .
7. ADJUSTING THE THERMOSTAT
Содержание 6341
Страница 3: ...5 6341 6343 7 6345 8 9 6345 6345 4 6342 6 6344...
Страница 24: ......