10 |
P a g e
Step 15: Carefully insert the UV lamp into the unit sliding it inside the quartz sleeve located inside the unit (do not
drop the lamp into the unit). Affix the connector into the gland nut by inserting the connector into the nut and
turning the connector approximately ¼ turn to lock the connector to the gland nut.
Figure 8. Connector
Step 16: Affix the captive ground screw to the ground lug on the UV unit to ensure proper grounding continuity.
Figure 9. Ground Screw Connection
Step 17: Your system is now ready to be plugged into the appropriate GFCI protected outlet. Plug the unit in and
refer to the “System Disinfection” section before any water is allowed to flow through the system.
System Disinfection
Now that the system is installed you will need to disinfect the lines throughout the entire home or facility. To
accomplish this, please follow these simple steps:
Step 1: Before performing this task, check to make sure that there are no “dead legs” in the lines throughout the
home as these can harbour bacteria. Also ensure that the UV system is powered-‐up and ready for operation before
you start this disinfection process.