REMOTE   ALARM   MODULE:   

Allows   for   a   signal   to   be   connected   to   a   

remote   monitor   such   as   a   buzzer,   light,   alarm   system,   PLC,   etc.,   via   a   pair   

of    contacts.    In    normal    operation    the    OK    and    COM    contacts    will    be   

connected,    and    in    a    fault    condition    (Low    UV,    Lamp    fail,    Power    Fail),    the   

Fault   and   COM   contacts   will   be   connected.   Maximum   Contact   Rating   is   1A-­‐

120VAC/VDC   (uses   16-­‐22   AWG).   

   

   

   

SOLENOID    CONNECTION    MODULE:   

Allows    the    integration    of    a   

NORMALLY   CLOSED   line   voltage   solenoid   valve.   Simply   affix   the   module's   

supplied   bare   lead   cord   to   the   solenoid   valve,   connect   the   power   cable   to   

the   electrical   outlet,   and   the   male   IEP   connector   to   the   female   IEP   port   on   

the   controller.   PLEASE   NOTE:   When   this   device   is   connected   to   a   CalUltra   

system   (without   the   UV   module),   then   the    solenoid   will   close   on   a   lamp   

failure   mode   only.   When   used   on   different   CalUltra   systems,   the   solenoid   

will    close    when    the    UV    level    drops    below    50%.    Also    note    that    in    cases   

where   emergency   use   of   untreated   water   is   required,   the   controller   can   be   

placed   into   a   manual   override   mode   allowing   for   the   flow   of   water   in   an   

alarm   condition.   

   

   

   

4-­‐20    mA    MODULE:   

Allows    for    a    4-­‐20mA    signal    transfer    of    the    UV   

output   to   a   remote   device   such   as   a   data   logger   or   computer.   Simply   plug   

the   supplied   cable   into   any   female   IEP   connections.   Two   screw    terminals   

are    supplied    to    connect    the    wire    that    leads    to    the    receiving    end    of    the   

signal.   As   the   distance   required   is   unknown,   no   wire   is   supplied   with   this   

system,   however   16-­‐22   AWG   is   required.

   

   

   

ETHERNET    MODULE:   

Allows    for    all    controller    functions    to    be   

connected   to   a   computer   via   an   Ethernet   cable.   This   module   is   currently   in   

development   and   is   not   available   at   this   point-­‐in-­‐time.

   

   

   

Warranty   Registration   

   

It   is   imperative   that   you   complete   the   warranty   registration   process.   This   not   only   registers   your   UV   disinfection   

system   for   the   provided   CALMAG   YORKSHIRE   LTD   warranty,   but   also   allows   Calmag   Yorkshire   Ltd   to   provide   you   

with   any   important   product   updates   or   technical   bulletins   concerning   your   product.   The   registration   process   is   a   

simple   process   and   can   be   done   online   at   

http://www.calmagltd.com

   or   by   filling   out   the   enclosed   warranty   card.   

Please   ensure   that   ALL   information   is   completed,   including   a   valid   e-­‐mail   address.   PLEASE   NOTE:   This   information   

is   for   the   sole   purpose   of   technical   support   for   your   disinfection   system   and   will   not   be   used,   or   sold,   to   any   other   

organisation   for   any   other   purpose.      

   

   

   

   

   

Содержание CALULTRA 12

Страница 1: ...Remember don t guess ASK Calming troubled waters...

Страница 2: ...ter supply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home with no chance of microbiological contamination This is chemical...

Страница 3: ...on Controller Overview Page 12 Operation Power up Sequence Page 13 Operation Remote Alarm Module Check Page 14 Operation Operational Screens Page 14 Operation UV Intensity Page 15 Operation Lamp Count...

Страница 4: ...ed to be installed indoors and away from leaking plumbing DO NOT plug the unit in if the system or any of the components are wet 9 The disinfection system should be directly installed into a ground fa...

Страница 5: ...mendations You can have your water tested at a private analytical laboratory or contact your local council for advice in regards to your local environmental health officer It is always recommended to...

Страница 6: ...litres per minute it is recommended to install the CALULTRA 79 UV unit There will be occasions where your home is using water at the pump s maximum capacity Location Step 1 Find a suitable location t...

Страница 7: ...or so that the rated flow of your particular CALMAG YORKSHIRE LIMITED system is not exceeded and the UV dose is not compromised The flow restrictor should be installed on the outlet port of the unit S...

Страница 8: ...P a g e Installation example unit connect ASSEMBLED ring installation unit unit ring unit unit...

Страница 9: ...ly and check for leaks Make sure the by pass valves are functioning properly and that the water is flowing through the unit The most common leak is from the O ring not making a proper seal on the unit...

Страница 10: ...d Screw Connection Step 17 Your system is now ready to be plugged into the appropriate GFCI protected outlet Plug the unit in and refer to the System Disinfection section before any water is allowed t...

Страница 11: ...inlet shut off valve shut this valve off to prevent water flow through the system If there is no inlet shut off valve turn off main water inlet valve and turn of water pump if you have one Step 2 Disc...

Страница 12: ...rew counterclockwise the sensor nut from the unit and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropy...

Страница 13: ...at the end of 12 months to replace the ultra violet bulb The Calmag Home Screen will then constantly scroll from right to left indicating that the unit is functioning correctly If the controller butt...

Страница 14: ...the front of the controller UV Intensity only for units equipped with a UV sensor If your system is equipped with a UV sensor the UV Output screens will indicate the level of UV intensity that is bei...

Страница 15: ...he flow of water if a solenoid valve is installed on the system Lamp Countdown Sequence The UV unit counts down the number of days until a lamp change is required The operation is as follows Once the...

Страница 16: ...lamp To perform this reset you must firmly depress the button on the front of the controller and then manually plug the power cord back into the wall outlet initiating power to the unit Keep holding...

Страница 17: ...Assuming the system has an optional 4 20 mA Module installed if at any time during the operation of the system a 4 20 mA module fails the controller will return both an audible and visual signal indi...

Страница 18: ...imply press the control button twice and the QR code screen will appear as follows Expansion Modules As shown earlier in this manual the CalUltra controllers incorporate an Infinite Expandability Port...

Страница 19: ...MODULE Allows for a 4 20mA signal transfer of the UV output to a remote device such as a data logger or computer Simply plug the supplied cable into any female IEP connections Two screw terminals are...

Страница 20: ...lug Type British Standard BS1363 Lamp Watts 15 22 39 42 Power watts 20 30 49 51 Replacement Lamp BULB B12 BULB B22 BULB B41 BULB B79 Replacement Sleeve SLEEVE QS12 SLEEVE QS22 SLEEVE QS41 SLEEVE QS79...

Страница 21: ...mitations of Warranty as outlined below CALMAG YORKSHIRE LIMITED s liability under this warranty shall be limited to repairing or replacing at CALMAG YORKSHIRE LIMITED s discretion without charge any...

Страница 22: ...ng the product Any defective product to be returned to CALMAG YORKSHIRE LIMITED must be sent carriage prepaid documentation supporting the warranty claim and or a Goods Return Number must be included...

Страница 23: ...23 P a g e...

Страница 24: ...24 P a g e Sandbeds Keighley Tel lmagltd com www calmagltd com Remember don t guess ASK Calming troubled waters Rev11 12...

Отзывы: