16   |   

P a g e

   

   

At   any   point   during   this   sequence,   the   audible   chirp   can   be   deferred   by   holding   the   controller   button   down   for   a   
period   of   five   seconds.   The   screen   shown   below   will   appear   for   five   seconds   indicating   that   the   audible   defferal   has   
been   activated   and   then   the   system   switches   back   to   the   current   lamp   change   or   lamp   expired   screen.   This   audible   
deferral   will   last   for   seven   days   after   which   then   the   alarm   will   sound   once   again.   This   audible   deferral   feature   can   
be    activated    as    many    times    as    you    wish.    PLEASE    NOTE:    During    the    condition    of    lamp    expiration    and    audible   
deferral,    the    water    may    be    unsafe    for    consumption    and    should    not    be    consumed    without    another    form    of   
disinfection.   

   

   

   

Lamp   Countdown   Reset   Sequence   

After   changing   the   lamp   on   the   CalUltra   system,   the   controller   must   be   reset   in   order   for   the   system   to   begin   its   
countdown   function   on   the   newly   installed   lamp.   To   perform   this   reset,   you   must   firmly   depress   the   button   on   the   
front   of   the   controller   and   then   manually   plug   the   power   cord   back   into   the   wall   outlet   initiating   power   to   the   unit.   
Keep   holding   down   the   button   for   five   seconds   until   you   hear   an   audible   chirp   indicating   the   controller   has   reset   
the   internal   timer.   Release   the   switch   and   the   lamp   countdown   feature   has   now   been   reset.   The   following   two   
screens   will   be   displayed   during   this   process.   

   

   

   

   

   

   

Failure   Modes   (if   applicable   to   the   system)   

The   CalUltra   controller   continuously   monitors   your   UV   system   and   if   there   is   a   problem   with   the   system   the   

controller   will   provide   both   a   visual   and   audible   signal   indicating   the   specific   fault   that   may   be   adversely   affecting   

the   operation   of   your   system.   The   fault   conditions   are   listed   in   a   priority   sequence   as   follows:   

   

   

LAMP   FAILURE:   

If   at   any   time   during   the   operation   of   the   system,   the   UV   lamp   fails   

to   be   illuminated,   the   controller   will   return   both   an   audible   and   visual   signal   indicating   

lamp   failure.   In   addition,   a   constant   audible   buzzer   will   sound   during   lamp   failure.   

   

   

   

   

   

   

   

Содержание CALULTRA 12

Страница 1: ...Remember don t guess ASK Calming troubled waters...

Страница 2: ...ter supply with a UV system gives you reassurance that your family will have access to safe drinking water throughout your entire home with no chance of microbiological contamination This is chemical...

Страница 3: ...on Controller Overview Page 12 Operation Power up Sequence Page 13 Operation Remote Alarm Module Check Page 14 Operation Operational Screens Page 14 Operation UV Intensity Page 15 Operation Lamp Count...

Страница 4: ...ed to be installed indoors and away from leaking plumbing DO NOT plug the unit in if the system or any of the components are wet 9 The disinfection system should be directly installed into a ground fa...

Страница 5: ...mendations You can have your water tested at a private analytical laboratory or contact your local council for advice in regards to your local environmental health officer It is always recommended to...

Страница 6: ...litres per minute it is recommended to install the CALULTRA 79 UV unit There will be occasions where your home is using water at the pump s maximum capacity Location Step 1 Find a suitable location t...

Страница 7: ...or so that the rated flow of your particular CALMAG YORKSHIRE LIMITED system is not exceeded and the UV dose is not compromised The flow restrictor should be installed on the outlet port of the unit S...

Страница 8: ...P a g e Installation example unit connect ASSEMBLED ring installation unit unit ring unit unit...

Страница 9: ...ly and check for leaks Make sure the by pass valves are functioning properly and that the water is flowing through the unit The most common leak is from the O ring not making a proper seal on the unit...

Страница 10: ...d Screw Connection Step 17 Your system is now ready to be plugged into the appropriate GFCI protected outlet Plug the unit in and refer to the System Disinfection section before any water is allowed t...

Страница 11: ...inlet shut off valve shut this valve off to prevent water flow through the system If there is no inlet shut off valve turn off main water inlet valve and turn of water pump if you have one Step 2 Disc...

Страница 12: ...rew counterclockwise the sensor nut from the unit and pull the sensor slowly out of the sensor port Step 6 Holding the sensor in your hand wipe the flat portion sensor face of the sensor with isopropy...

Страница 13: ...at the end of 12 months to replace the ultra violet bulb The Calmag Home Screen will then constantly scroll from right to left indicating that the unit is functioning correctly If the controller butt...

Страница 14: ...the front of the controller UV Intensity only for units equipped with a UV sensor If your system is equipped with a UV sensor the UV Output screens will indicate the level of UV intensity that is bei...

Страница 15: ...he flow of water if a solenoid valve is installed on the system Lamp Countdown Sequence The UV unit counts down the number of days until a lamp change is required The operation is as follows Once the...

Страница 16: ...lamp To perform this reset you must firmly depress the button on the front of the controller and then manually plug the power cord back into the wall outlet initiating power to the unit Keep holding...

Страница 17: ...Assuming the system has an optional 4 20 mA Module installed if at any time during the operation of the system a 4 20 mA module fails the controller will return both an audible and visual signal indi...

Страница 18: ...imply press the control button twice and the QR code screen will appear as follows Expansion Modules As shown earlier in this manual the CalUltra controllers incorporate an Infinite Expandability Port...

Страница 19: ...MODULE Allows for a 4 20mA signal transfer of the UV output to a remote device such as a data logger or computer Simply plug the supplied cable into any female IEP connections Two screw terminals are...

Страница 20: ...lug Type British Standard BS1363 Lamp Watts 15 22 39 42 Power watts 20 30 49 51 Replacement Lamp BULB B12 BULB B22 BULB B41 BULB B79 Replacement Sleeve SLEEVE QS12 SLEEVE QS22 SLEEVE QS41 SLEEVE QS79...

Страница 21: ...mitations of Warranty as outlined below CALMAG YORKSHIRE LIMITED s liability under this warranty shall be limited to repairing or replacing at CALMAG YORKSHIRE LIMITED s discretion without charge any...

Страница 22: ...ng the product Any defective product to be returned to CALMAG YORKSHIRE LIMITED must be sent carriage prepaid documentation supporting the warranty claim and or a Goods Return Number must be included...

Страница 23: ...23 P a g e...

Страница 24: ...24 P a g e Sandbeds Keighley Tel lmagltd com www calmagltd com Remember don t guess ASK Calming troubled waters Rev11 12...