This setup is for dual slide gates. A single button press of the remote control can open both gates.
This requires 2 gate operators. One gate operator is the "Primary", and the other is the "Secondary".
All accessories including remote controls, photocell sensors, loop detectors, etc., must be installed
on the PRIMARY gate operator only. Only one photocell sensor is required.
DATA-
DATA+
DATA-
DATA+
Dual Gate Setup
1. On the Secondary gate operator circuit board, set dip switch #5 to ON (Figure 1).
2. Press the reset button on the Secondary gate operator circuit board.
3. A 18-22 gauge, 2 conductor, stranded, copper, electrical wire is required.
4. Locate the DATA- and DATA+ green terminal on the bottom left of the circuit board. (Figure 2). Use
a flathead screwdriver to release the 2 locks on the top of the green terminal.
5. Using the electrical wire, connect the DATA+ on the primary gate opener, to the DATA+ on the
secondary gate opener. Connect the DATA- on the primary gate opener to the DATA- on the
secondary gate opener. The M/S link LED light should now be lit on both circuit boards.
6. Use the flathead screwdriver to close the two locks on the top of the green terminal.
7. Place the cable underground in an electrical conduit. This conduit must be separate from the
main 110-120V AC electricity conduit. Finished.
21
Figure 2
Electrical Conduit
Figure 1
Содержание CM3
Страница 41: ......