Photocell Sensor Wiring
Notes
• The default photocell sensor range is 30'. For a longer range, upgrade to the CM9-487,
which has a max range of 50'.
• The photocell sensor cannot be used for a detection area less than 0.5'.
• If you need to place the photocell sensor further away, extend the photocell sensor
wires by joining (splicing) with another 20-22 AWG wire.
15
LED INDICATORS
Yellow and Red On
Yellow Off Red On
Yellow and Red Off
Relay is energized and signal is aligned and stable
Relay is energized, reflector is on the edge of the
signal path
Beam is obstructed or sensor is not aligned with
the reflector
LED
4-Wire
Wiring Diagram
Black
Blue and White
Brown
MON-CLOSE
COMMON
MON-24VDC
3
-Wire
Wiring Diagram
Gray
Blue
Brown
MON-CLOSE
COMMON
MON-24VDC
Photocell Sensor LED Indicators