A. On your circuit board find the 1-8 Dip Switches, turn the nearby OFF/ON switch to ON.
B. Unscrew the back of the remote control to gain access to the control board. You should see
1-8 dip switches. Each switch has 3 positions: up, middle, bottom. Flip these 1-8 switches to
any random position you'd like, see Figure A.
By default, the remote controls are already connected to the gate operator. You do not need to do
any of the following steps unless you are adding more remote controls.
This gate operator can add up to 50 different remote controls. To add more than 50 remote controls,
add a receiver, which can add up to 100 additional remote controls. Calimet remote controls use 418
MHz frequency with a 300' max distance.
There are two ways to connect your remote control: Learn & Dip Switch.
Learn
Connect using Learn On your gate operator circuit board, look for the study button. Press and hold
the button on the remote control. Press and hold the study key until the flashing light turns solid,
about 2 seconds. Then release both buttons immediately. Done, the remote is now connected to the
gate opener.
Removing all existing remote controls Press the STUDY key on the gate operator circuit board and
hold for 8 seconds. Done. All remote controls are now removed.
Dip Switch
Only the CM9-509 red remote controls can be installed using the dip switch method.
Remote Controls
25
Figure A
C. On the gate opener control board, set the same 1-8 dip switch combination on the as you did on
the remote.
D. Finished.