Page 23
6.
Adapting
the
convection
air
volume
to
the
room volume to be heated
The convection air volume can only be adapted to the room volume to be heated
in the semi-automatic mode. The convection air fan speed is always coupled to the
heating output in automatic mode.
This allows you to adapt the air circulation to the room volume being heated. Very
large or very high rooms require increased air circulation to achieve a uniformly dis-
tributed temperature across the entire room.
If the heating output is set to
L
ow
the convection air fan can be set to the stages
L
ow,
M
edium
or
H
igh
.
If the heating output is set to
M
edium
the convection air fan can be set to the stages
H
igh,
M
edium
or
L
ow
.
If the heating output is set to
H
igh
the convection air fan can be set to the stages
H
igh
or
M
edium
.
The default setting of the convection air fan is analogue to that of the set heating
output. If the heating output is set to
M
edium
this means that the convection air fan
is also operating in the output stage
M
edium
.
The currently selected settings are shown with a bar symbol.
6.1. Setting the heating output/convection fan
These parameters are only available in the semi-automatic operating mode!
Press the button.
Scroll to page K12 with the button.
The heating output can be set with the or buttons.
The convection fan can be changed with the or but-
tons.
Use the button to leave the customer menu and save the
parameters.
The menu is automatically closed and the parameters
saved after 60 seconds.