Page 16
4.6. Setting the date and time
The Service menu is displayed with the and or and buttons.
(Press and hold down any arrow key. Briefly press the Menu button and then release
the arrow key again).
The various menu items can be displayed with the or buttons.
Scroll to page S210 with the button.
Enter the menu with the button.
Use the and buttons to set the
required date.
Use the or buttons to scroll onward from Date to Time.
4.7. Safety equipment
The cooling phase starts immediately if there is a malfunction and the fire will go out
within several minutes. A restart is only possible manually after the malfunction has
been resolved (press the Start button).
4.7.1. Power failure
The control unit activates and maintains the cooling phase if there is a power failure.
The device will then start operating again by returning to the start phase, even if the
power failure only lasted a few seconds.
A slight amount of smoke may be produced during a power failure, but does not
pose any danger as it is produced by the small amount of fuel still in the burn grate.
4.7.2. No flame formation during the start phase
The stove switches off automatically if no flame is formed during the start phase and
if the exhaust gases do not reach a minimum temperature of 60°C (insufficient fuel
supply).
4.7.3. Device overheating
A high-temperature monitor is located in the pellet chute and the combustion
chamber, these can independently switch off the pellet supply if overheating occurs.
The exhaust and convection air fans continue operating in this case and ensure that
the stove cools down rapidly.
The stove switches off automatically if no flame is formed during the start phase and
if the exhaust gases do not reach a minimum temperature of 60°C (insufficient fuel
supply).