9.3 Option –160: RTCA/DO-160 Tests
The RTCA/DO-160 Option is made up of both firmware that resides in the power source and the
MXGui Windows application program. The firmware covers revision D and can be used from
the front panel or under MXGui control. Revision E is implemented through th
e MXGui only.
The user interface for each implementation is different. The revision D tests can be operated
directly from the power source’s front panel or through the supplied MXGui program. The
Revision E tests can only be operated through the MXGui windows software. Thus, for Rev E
use, a Windows PC and interface – RS232 ,USB, LAN or GPIB (recommend) - is required.
Section 9.3.1 covers operation of the firmware based revision D tests.
For information regarding the operation of the DO160 revision E tests with the MXGui, please
refer to the Avionics Software Manual (CI part no. 4994-971 included on CDROM). Note that
future updates of the MXGui may include overlapping coverage for revision D in the software as
the MXGui program is designed to support all revisions. For now, revision D has no associated
data files in the MXGui but does have it’s own user interface control screen.
9.3.1 Option –160: RTCA/DO160 rev D Tests (Firmware)
9.3.1.1 General
The RTCA/DO-160 option is capable of performing all sections of RTCA/DO-160D, Section 16
and EUROCAE-14D / RTCA DO160D, Section 16 for the AC Source signal. A selection is made
available to specify the type of standard, and groups.
Through out this document, Groups 1 through 3 will be used to refer to EUROCAE-14D
standard.
9.3.1.2 Initial Setup
Nominal parameters for the AC Power source are as follows:
Output Voltage
115V L-N or 230V L-N
Output Frequency
360 Hz to 800 Hz
Nominal parameters for the DC Power source are as follows:
Output Voltage
28V or 14V L-N
A setting outside these nominal values will disable the test and will prevent accessing to its
Menu screens. To access the test for the 230V L-N, the power source must be capable of
programming 360V.
9.3.1.3 Tests Performed
Available tests are divided into Normal, Abnormal and Emergency.
9.3.1.3.1 NORMAL STATE
AC Source:
1. Normal State Voltage and Frequency test
2. Voltage unbalance test
3. Waveform Distortion test
4. Voltage Modulation test
MX Series
191
Содержание MX30-1
Страница 4: ...User Manual Rev AJ California Instruments 4 MX Series ...
Страница 33: ...User Manual Rev AJ California Instruments MX Series 33 ilter option schematic Figure 2 12 MX output f ...
Страница 34: ...User Manual Rev AJ California Instruments Figure 2 13 MX45 Output Noise 10 KHz 1 MHz 34 MX Series ...
Страница 50: ...User Manual Rev AJ California Instruments Figure 3 11 MX135 or MX135 MB Output Wiring Rear view 50 MX Series ...
Страница 147: ...User Manual Rev AJ California Instruments Output Status Available on top assembly 7003 427 only MX Series 147 ...
Страница 148: ...User Manual Rev AJ 148 California Instruments MX Series Figure 5 2 MX Series Detailed Block Diagram ...
Страница 149: ...User Manual Rev AJ MX Series California Instruments 149 Figure 5 3 Power Module Detailed Block Diagram ...
Страница 195: ...User Manual Rev AJ California Instruments Figure 9 4 Voltage Modulation MX Series 195 ...