![California Instruments MX30-1 Скачать руководство пользователя страница 129](http://html1.mh-extra.com/html/california-instruments/mx30-1/mx30-1_user-manual_3472136129.webp)
User Manual – Rev AJ
California Instruments
7
SOURCE field and select IMM. We will cover additional trigg
T field and press the ENTER key. The display that y
u are in CONT trigg
. Move the cursor to the TRIG
er
modes later.
8. Move the cursor to the STAR
ou
selected will be shown. If yo
er mode, the data will be updated about
once per second.
You can return to the HARMON
display the data in a different for
to
the VIEW field. Pressing the EN
acquisition. (This is true even if y
must go through the START field
4.6.1.2
ICS/TRACE ANALYSIS screen by pressing the ENTER key. To
mat, change to the selections you want and move the cursor
TER key will re-display the data without triggering a new
ou were in CONT trigger mode.) To start a new acquisition, you
instead.
Analyzing FFT data
The data displays available for F
table displays, the UP and DOW
vertically. The knob has no func
mode. The triangle on the left edge of
FT data allow you to scroll through the entire data set. For
N arrow keys may be used to scroll through the table data
tion while in this display
the LCD screen points to the current position in the table.
: Scrolling Through Tabular FFT Data
Figure 4-36
Bar chart format FFT data displays show the same data in a graphical format. While the
amplitude information is shown graphically, phase data is only displayed in numeric form to the
left for the currently selected harmonic component. The display can show up to 24 components
at a time. The triangle at the bottom of the display shows the currently selected component for
which numeric data is shown on the left. This data includes the harmonic number (DC through
50), the absolute or relative amplitude (depending on selected VIEW mode) and the phase
angle with respect to the fundamental. The knob can be used to scroll through the display
horizontally. The UP and DOWN cursor keys have no effect in this display mode.
Counter
Clock
wise
Clock
wise
INCR
DECR
Figure 4-37: Scrolling through bar chart FFT Data
Arrow indicator
can be moved up
or down using
UP/DOWN cursor
keys.
Arrow indicator
points to
harmonic for
which readout is
shown on the
left. Can be
moved with
knob.
MX Series
129
Содержание MX30-1
Страница 4: ...User Manual Rev AJ California Instruments 4 MX Series ...
Страница 33: ...User Manual Rev AJ California Instruments MX Series 33 ilter option schematic Figure 2 12 MX output f ...
Страница 34: ...User Manual Rev AJ California Instruments Figure 2 13 MX45 Output Noise 10 KHz 1 MHz 34 MX Series ...
Страница 50: ...User Manual Rev AJ California Instruments Figure 3 11 MX135 or MX135 MB Output Wiring Rear view 50 MX Series ...
Страница 147: ...User Manual Rev AJ California Instruments Output Status Available on top assembly 7003 427 only MX Series 147 ...
Страница 148: ...User Manual Rev AJ 148 California Instruments MX Series Figure 5 2 MX Series Detailed Block Diagram ...
Страница 149: ...User Manual Rev AJ MX Series California Instruments 149 Figure 5 3 Power Module Detailed Block Diagram ...
Страница 195: ...User Manual Rev AJ California Instruments Figure 9 4 Voltage Modulation MX Series 195 ...