GPIB/RS232 (incl. USB/LAN) SETUP menu
Figure 5-18: GPIB/RS232 SETUP Menu
The GPIB/RS232 SETUP menu may be used to change the interface parameter settings for both the IEEE-
488 interface and the RS232, USB or LAN interface. The number of interfaces available will depend on
the specific model and options as well as the time of manufacture. Older BPS models do not offer USB or
LAN interfaces. Newer models can be equipped with as many as 4 different interfaces although only one
can be used at the same time.
Refer to the BPS Series Programming Manual P/N 7003-961 distributed in Adobe PDF format on the
same CD ROM as this user manual for more details on using the RS232, USB or LAN interface.
The following parameters can be set from this menu:
GPIB ADDRESS
Sets the IEEE-488 address used by the AC source. The address value
can be set from 0 through 31. Address 0 is often reserved for the
IEEE-488 controller. The factory setting is address 1. Once changed,
the IEEE-488 address is retained in nonvolatile memory.
RS232 BAUDRATE
This field can be used to set the RS232 baud rate to either 9600,
19,200, 38,400, 57600 or 115,200 baud. The baud rate set on the AC
source must match the one programmed for the communications port
of the controller. Baud rates higher than 115200 are provided for the
USB and LAN interface modes only. The same setting is used for
USB and LAN modes. For use with either USB or LAN, the baud rate
in this screen must be set to
460800
. See UTILITY 2 screen for other
LAN setup parameters.
RS232 DATA
This field is used to set the number of data bits to either 7 or 8.
Factory setting is 8 bits. This value must match the number of data
bits set on the communications port of the controller. For USB or
LAN use, always use factory settings.
RS232 PARITY
This field is used to set the parity. Available options are Even (E),
Odd (O) or no parity (N). Factory setting is No parity. This value must
match the parity set on the communications port of the controller. For
USB or LAN use, always use factory settings.
RS232 STPBITS
This field is used to set the number of stop bits used on the serial port.
Available options are 1 or 2 bits. Factory setting is 1 stop bit. This
value must match the parity set on the communications port of the
controller. For USB or LAN use, always use factory settings.
The number of start bits is always fixed to 1 bit.
Содержание BPS Series
Страница 1: ...M440077 01 Rev A www programmablepower com BPS Series AC Power Source User Manual...
Страница 26: ...AMETEK Programmable Power BPS Series User Manual M440077 01 Rev A 26...
Страница 36: ...AMETEK Programmable Power BPS Series User Manual M440077 01 Rev A 36 Figure 4 1 BPS75 BPS90 Power Source Photo...
Страница 111: ...User Manual AMETEK Programmable Power BPS Series 111 Figure 6 2 BPS90 Series Detailed Block Diagram...
Страница 112: ...User Manual AMETEK Programmable Power BPS Series 112 Figure 6 3 Power Module Detailed Block Diagram...
Страница 114: ...User Manual AMETEK Programmable Power BPS Series 114 Figure 6 4 Power Module Layout...