background image

© 2010 Schaudt GmbH, Elektrotechnik & Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Phone +49 7544 9577-0, T49 7544 9577-29, www.schaudt-gmbh.de

811.598 BA / EN

Situation: 25.06.2010

0

Instruction Manual Electrobloc EBL 269

Instruction manual

Electrobloc EBL 269

Table of contents

1

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2

Safety information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

3

Description and appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4

Suitable accessories (not supplied) . . . . . . . . . . . . . . . . . . . . . . . . 5

5

Electrical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

6

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

7

Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

8

Shutting down the system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

9

Changing the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

10

Technical faults, possible causes and remedies . . . . . . . . . . . . . . 8

11

Customer service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

12

Block diagram - for specialist workshop only . . . . . . . . . . . . . . . . 10

13

Fault report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Summary of Contents for Electrobloc EBL 269

Page 1: ...L 269 Instruction manual Electrobloc EBL 269 Table of contents 1 Introduction 2 2 Safety information 2 3 Description and appropriate use 4 4 Suitable accessories not supplied 5 5 Electrical data 5 6 Operation 5 7 Maintenance 7 8 Shutting down the system 7 9 Changing the battery 7 10 Technical faults possible causes and remedies 8 11 Customer service 9 12 Block diagram for specialist workshop only ...

Page 2: ...ruction manual must be followed Any technical faults affecting the safety of persons or of the Electrobloc must be dealt with immediately by qualified personnel Failure to comply with this sign may lead to the endangerment of per sons Failure to comply with this sign may damage the device or the connected consumers This sign indicates recommendations or special features The electrical system of th...

Page 3: ...ing the battery selector switch If the living area battery is changed or removed the frost protection valve on the heater system opens automatically Water may be lost For more information see the instruction manual of the heater system Before and after shutdown the living area battery must be fully recharged to avoid battery damage For this purpose the vehicle must be connected to mains supply for...

Page 4: ...otorhome including accessories There are connections for an auxiliary charging unit and a solar charge regu lator Fig 1 Electrobloc EBL 269 front view 1 Mains connection 2 Flat vehicle fuses 3 Battery selector switch 4 Connections block 8 5 Connections block 7 6 Connections block 6 7 Connections block 4 Solar charge regulator 8 Connections block 5 Control and switch panel 9 Connections block 3 Aux...

Page 5: ...witch at the control and switch panel Type no Fuse value 911 520 2 5 A slow blow 911 525 2 5 A slow blow 911 521 3 15 A slow blow 911 526 3 15 A slow blow Mains connection 230 V AC 10 47 to 63 Hz sinusoidal protection class I Suitable batteries 6 cell lead acid or lead gel batteries of at least 55 Ah Current carrying capacity 12 V outputs No more than 90 of the rated current of the appropriate fus...

Page 6: ...ual of the control and switch panel 6 2 Additional functions Automatic switch function for AES compressor refrigerator This relay supplies the AES compressor refrigerator with power from the starter battery when the vehicle engine is running and the D connection is live An AES compressor refrigerator is powered by the living area battery when the vehicle engine is switched off Automatic switch fun...

Page 7: ...cid to lead gel batteries You cannot change from lead gel to lead acid batteries Ask your dealer for advice Before and after shutdown the living area battery must be fully recharged to avoid battery damage For this purpose the vehicle must be connected to mains supply for a minimum of 12 hours with an 80 Ah battery and 24 hours with a 160 Ah battery Do not operate the Schaudt solar charge regulato...

Page 8: ...tor switch damages the living area battery Disconnect the Electrobloc from the mains before adjusting the battery selector switch Fault Possible cause Remedy Living area battery is not charged during 230 V operation battery voltage constantly below 13 3 V No mains voltage Switch on the automatic fuse in the vehicle Have the mains voltage checked Defective Electrobloc Call customer service Living a...

Page 9: ...robloc Call customer service Defective refrigerator Have the refrigerator checked Solar charger does not work power supply and engine are off Solar charge regulator not plugged in Plug in the solar charge regulator Defective fuse or wiring Have the fuse and wiring checked Defective solar charge reg ulator Have the solar charge reg ulator checked 12 V power supply in the living area does not work 1...

Page 10: ...block 8 Starter battery 12 V off Pump switch Spare 12 V on 12 V indicator Light Negative living area battery sensor MNL socket cap 5x block 2 Starter battery for refrigerator Negative living area battery sensor Living area battery sensor Negative starter battery for refrigerator Absorber refrigerator D input MNL socket cap 4x block 1 D base Negative refrigerator Compressor refrigerator Absorber re...

Page 11: ...ive device together with the completed fault report There is the following defect please tick Other remarks Device type Type no please enter EBL 269 Battery not being charged during power operation Battery not being charged during mobile operation The following electrical con sumers do not work Constant fault Temporary fault loose con tact ...

Page 12: ...12 Situation 25 06 2010 811 598 BA EN Instruction Manual Electrobloc EBL 269 ...