FEATURES

APPLICATIONS

Indirect Lighting

LENS

Clear

LENGTH

Built to Order (± 0.25” Tolerance)

CONSTRUCTION

Aluminum Extrusion

FINISH

White Powder Coated

DRIVER

Remote

WEIGHT

4.80 lbs per foot

MOUNTING

Aircraft Cable

LISTING

Dry or Damp Location
UL1598, CSA C22.2#250.0
UL8750, CSA250
UL2108, CSA C22.2 #9

TEMPERATURE 

RATINGS

Operating / Startup:

 -20° to 48°C (-4° to 120°F)

Storage:

 -40° to 76°C (-40° to 170°F)

• Indirect lighting
• 24 Volts DC for easy and safe installation 
• Long life, energy efficient LEDs
• Available in 4 Watts up to 24 Watts Per Foot 
• Can be ordered to specific lengths for when exact dimensions are known 
   

Example:

 10 x 10’6” (product is shipped in 8’ max luminaires)

• Available for indoor (DRY) and (DAMP) rated installations

PRODUCT INFORMATION

• Electric Hammer Drills (optional)    
• 14.4 to 28 Volt Cordless Drills          
• Phillips Bits - Sufficient Quantity    
• Utility Knife
• Electrical Cords                   
• Marker 
• Wire Strippers

• Long Nose Pliers
• Drill Bits - Concrete or Wood
• Electrical Three Ways
• Safety Glasses
• Measuring Tapes
• Chalk Line 

             

• ALS500T-DBR requires a remote driver. The driver may be mounted on top
   of the luminaire or in a remote location.
• Drivers are 120V - 277V (UNV) Input Voltage and 24VDC Output Voltage
• To calculate driver size, determine Watts per Foot.
   

Example:

 4W per Foot

• Determine Length in Feet.
   

Example:

 20’

• To calculate Load, Multiply Watts per Foot x Length in Feet
   

Example:

 4W x 20’= 80W. The Load of the driver is 80 Watts.

• Maximum load for a Class 2 low voltage luminaire is 96 Watts

• ALS500T-DBR can be mounted to concrete, wood, or metal using proper
   mounting hardware.
• Ensure surface material can support the weight of the luminaire.

ELECTRICAL

INSTALLATION RECOMMENDATIONS

INSTALLATION TOOL REQUIRED

Содержание alumLEDs ALS500T-DBR-HC

Страница 1: ...ing 24 Volts DC for easy and safe installation Long life energy efficient LEDs Available in 4 Watts up to 24 Watts Per Foot Can be ordered to specific lengths for when exact dimensions are known Examp...

Страница 2: ...o Power Source Circuit 2H White Circuit 1H Gray KEY A Standard Length Luminaire runs are constructed in 8 segments B Custom Length Any required length that is not 8 Typically the last segment of a run...

Страница 3: ...to make changes or withdraw specifications without prior notice 5 20 2021 Rev 3 Page 3 of 11 ALS500T DBR HC INSTALLATION INSTRUCTIONS Diagram of Assembly Aircraft Cable Hard Ceiling Hard Ceiling Trim...

Страница 4: ...such as drywall or plywood 4 Secure Aircraft Cable Assemblies to mounting surface The top of the assembly should rest approximately 7 above ceiling line Ensure assembly is centered between the T Bars...

Страница 5: ...ct vary Always confirm wiring diagram from driver installation instructions before connecting 17 If applicable install mud in end cap at end of run The mud in end cap is used when the end of the lumin...

Страница 6: ...5 Aircraft Cable Assembly 4 ALS500T DBR 6 8 Aircraft Cable Assembly 4 For luminaires 1 5 long use 2 Aircraft Cable Assemblies per luminaire Install each assembly about 4 from each end of luminaire No...

Страница 7: ...lade for cutting metal Note If applicable remove Connector Blocks from extrusion before cutting 1 Position luminaires together and align the screw of the Male Block to meet the Female Block Tighten Al...

Страница 8: ...ween trim and fixtures not aligned Install Trim Retention Springs to ceiling trim Use one clip per 2 or two clips per segment under 4 Install clips 4 from each edge evenly spaced 3 Measure and cut a 2...

Страница 9: ...ate how much more film will be needed Make small cuts at the end of the film and test fit it Repeat if necessary until the film meets the end cap flush 5 Check along entire run that Reflective Film is...

Страница 10: ...ath is formed between the positive and negative wires the multimeter will beep flash or read 0 ohms Troubleshoot to identify the malfunction in the line If there is no conductive path the multimeter w...

Страница 11: ...ctory for any malfunctions Do not attempt to repair Only use alumLEDs with specified rated voltages Do not exceed the specified voltage for any alumLEDs luminaire Do not use alumLEDs extrusion as a ra...

Отзывы: