SPECIFICATION SUMMARY

7507 series

CONTECA

®

 EASY ULTRA 

 direct heat meter, compliant with directive 2014/32/EU (MID)

, for use in heating and air-

conditioning systems, with the following specifications: 

ultrasonic

 volume meter for hot water (maximum temperature 90 °C) with 

pulse output, NTC type temperature probe, data viewing on 8-digit display, working temperature range 10–90 °C, protection class 

IP 54, transmission via 

TWO-WAY

  Bus in accordance with M-Bus protocol over RS-485 or MODBUS RTU over RS-485, electric 

supply 24 V (ac) 50 Hz - 1 W. 

Options:

 up to 2 additional pulse inputs - up to 2 pulse outputs.

Code 755810

Metering of refrigeration units. Upon activation of the software module, CONTECA

®

 EASY is able to meter heating and cooling 

units, on the evaluation of the temperature difference reversal, in separate registers for both the current values and for the 

logged files.

Code 755881 – 755882

The single pulse output code 755881 or the double pulse output code 755882, allow transferral of heating and cooling energy 

values to a generic logger.

 The pulse weighs 1 kWh

. The pulse output with no potential is 

open collector

 with pulse time 

120 ms - Vmax 24 V (dc) - 50 mA.

Code 755825

The optional pulse inputs (up to two) allow acquisition of generic meter consumption values (e.g. gas or electricity).

 

The generic 

pulse input should be class IB, 

with no potential

, maximum frequency 1 Hz.

Code 755826

Option for enabling DHW metering via checking of the flow rate scan for domestic water systems equipped with a recirculation 
system. The option distinguishes the actual DHW flow rates from inaccurate or gross recirculation values, with the aim of providing 
the exact domestic hot water consumption figure.

Code 755890

Electronic 8-digit LCD totaliser equipped with cover plate for

 three-slot recessed electric box

. Lithium battery: life 8 years 

- max. frequency 20 Hz. Suitable for pulse outputs code 75588.. Maximum cable length (2x1 mm

2

) (not supplied): max. 75 m. 

Cable in dedicated raceway.

Code 755010

Compact touch-screen CONTECA

®

 TOUCH controller, equipped with RS-232 - RS-485, USB and LAN port, with user 

supervisor function (max. 250) and daily logging of consumption data. Enabled for the management of alarm and remote 

activation SMS messages and for the automatic daily transmission of data to FTP server via email. Electric supply 230 V (ac). 

Working temperature range 10–35 °C with no dust.

Code 750350

Regulator for acquiring and logging data with the following specifications: communication over RS-485 physical level in 

M-Bus protocol. Electric supply: 24 V (dc) - 3 W or 24 V (ac) - 3 W. Local access via PC and remotely via integrated web 

page. Daily data storage: 10 years. Mounting on 35 mm DIN rail (EN 60715). 2 Ethernet ports. Reports in .XLS or .CSV 

format. Maximum number of users: 250. Ambient temperature range 0–50 °C. UMTS router with the following specifications: 

electric supply: 100/240 V (ac) / 9 V (dc) - 7 W, LAN: wireless AP, router switch with 4 ports with firewall. Dynamic IP 

management via Dyn DNS. Dimensions (H x W x D): 36 x 85 x 100 mm. Certification: CE, EN 60950 - 1.

Code 750450 

Regulator for acquiring and logging data with the following specifications: communication over RS-485 physical level in M-Bus 

protocol. Electric supply: 24 V (dc) - 3 W or 24 V (ac) - 3 W. Integrated web interface. Daily data storage: 10 years. Mounting 

on 35 mm DIN rail (EN 60715). 2 Ethernet ports. Reports in .XLS or .CSV format. Maximum number of users: 250. Ambient 

temperature range 0–50 °C.

Содержание CONTECA EASY ULTRA

Страница 1: ...culator unit an ultrasonic flow meter and two temperature probes The CONTECA EASY ULTRA meter is extremely simple to install and requires no special maintenance The flow is measured using the two way...

Страница 2: ...h l h l h C kWh PN Qp Qi Qs m m C K C 90 preferably horizontal class OA OC in accordance with EN1434 2 see table 1 and 2 see table 1 and 2 see table 1 and 2 lithium battery life 12 years p Code The CO...

Страница 3: ...e while the return probe blue label should be on the return pipe At the end of the installation process the main heat meter components electronics unit temperature probes and volume meter should under...

Страница 4: ...protect the volume meter By observing the instant flow rate and flow return temperature difference values significantly lower flow rate compared to the nominal value and significantly higher temperat...

Страница 5: ...duration 120 ms Vmax 24 V dc 50 mA 755882 2 3 OUT 1 Open collector pulse output for HEATING units GND 2 duration 120 ms Vmax 24 V dc 50 mA 755881 755882 4 NOT used 5 6 IN 4 fourth pulse input generic...

Страница 6: ...input blue wire white wire Enery pulse outputs codes 755881 755882 2 3 Remote heating units totaliser output kWh OC type 1 2 Remote cooling units totaliser output kWh OC type These outputs can be conn...

Страница 7: ...ption with optional code 755826 2nd DCW pulse consumption 3rd pulse consumption with optional code 755825 Flow rate Power Flow temperature Return temperature Temperature difference DHW flow rate with...

Страница 8: ...change K V volume change l V N P where N number of pulses P single pulse value per litre Operating specifications 1 In order to protect against spurious measurements or undesired metering the meterin...

Страница 9: ...ass the thread through the hole on the probe and the pocket and twist it E Wind the thread as illustrated in the figure so that once lead sealing is complete the cap cannot be unscrewed without breaki...

Страница 10: ...bob D Pass the thread through the hole on the probe and the pocket and twist it E Wind the thread as illustrated in the figure so that once lead sealing is complete the cap cannot be unscrewed without...

Страница 11: ...SY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY 11 M Bus M Bus Master 230 V ac 755058 M Bus RS 485 slave converter Used to ad...

Страница 12: ...ied out by the user removed Maximum number of users 250 Datalogger specifications Electric supply 24 V dc 10 24 V ac 3 W 2 Ethernet outputs ETH1 PoE ETH2 Working temperature range 0 50 C Mounting 35 m...

Страница 13: ...755881 Acquisition board Terminals 2 3 Heating units 7507 Terminals 2 3 Heating units Terminals 1 2 Cooling units CALEFFI ENERGY kWh 2 6 0 V HEATING UNITS output COOLING UNITS output GND 1 2 3 4 5 6...

Страница 14: ...20030 PULSE MONITOR Pulse logger Electric supply lithium battery 6 digit display with user key Daily data saving Tamper proof seal and sensor Enables acquisition of a pulse output from the heat meter...

Страница 15: ...ues with the aim of providing the exact domestic hot water consumption figure Code 755890 Electronic 8 digit LCD totaliser equipped with cover plate for three slot recessed electric box Lithium batter...

Страница 16: ...ULTRA 7507 series CONTECA EASY ULTRA heat meters in the 7507 series conform to the requirements of directive 2014 32 EU better known as MID acronym for Measuring Instrument Directive Production proce...

Отзывы: