background image

DATA CENTRALISATION

(B) Datalogger DATA EASY TELE

(C) DATA EASY datalogger

750350

24 V (ac/dc)

750450

24 V (ac/dc)

755010

Bus cable

CONTECA

®

TOUCH datalogger

230 V (ac)

230 V (ac)

24 V (ac)

2-way 1 mm bus transmission line

2

(755855 LSC)

Centralised 24 V (ac) electric supply line

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

Architecture of centralisation

Local acquisition

Remote acquisition

Remote acquisition

Controller 

code 755010

1

st

 line

2

nd

 line

3

rd

 line

4

th

 line

7504..

L2

L1

LA

LB

LN

LA + LB + ... + LN + L1 + L2 < 1.200 m

Hydronic Solutions

CALEFFI

Code 755010 - Serial

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

RS485

EASY

CO

N

TECA

EASY

11

M-Bus

M-Bus 

Master

M-Bus 

Master

230 V (ac)

24 V (ac)

230 V (ac)

CONTECA® 

environment

Master

RS485 network

7550

58

M-Bus - RS-485 slave converter

Used to adapt and galvanically separate two transmission standards 

(M-Bus and RS-485). It allows direct connection of CONTECA

®

 EASY 

meters to an M-Bus transmission line, making them visible as slave 

devices. 

Electric supply: 230V (ac) - 9VA

Operating temperature: -10 – 60 °C.

7550

58

M-Bus/RS-485 slave converter

Code

Application diagram for M-Bus slave converter - RS-485 code 755058

The software protocol used for supervisor/CONTECA

®

 environment 

interfacing utilises the M-Bus standard (complies with EN 1434 part 3).

N.B.

:

The transmission bus, code 755855 LSC, is two-way (cross-section 2 
x 1 mm

2

). The controller allows 

max. 250 users

.

The 

maximum length

 of each individual section is 

1200 m

.

It is possible to lay 

up to 4 separate sections 

using the MULTIPLEXER, 

code 755005.

Содержание CONTECA EASY ULTRA

Страница 1: ...culator unit an ultrasonic flow meter and two temperature probes The CONTECA EASY ULTRA meter is extremely simple to install and requires no special maintenance The flow is measured using the two way...

Страница 2: ...h l h l h C kWh PN Qp Qi Qs m m C K C 90 preferably horizontal class OA OC in accordance with EN1434 2 see table 1 and 2 see table 1 and 2 see table 1 and 2 lithium battery life 12 years p Code The CO...

Страница 3: ...e while the return probe blue label should be on the return pipe At the end of the installation process the main heat meter components electronics unit temperature probes and volume meter should under...

Страница 4: ...protect the volume meter By observing the instant flow rate and flow return temperature difference values significantly lower flow rate compared to the nominal value and significantly higher temperat...

Страница 5: ...duration 120 ms Vmax 24 V dc 50 mA 755882 2 3 OUT 1 Open collector pulse output for HEATING units GND 2 duration 120 ms Vmax 24 V dc 50 mA 755881 755882 4 NOT used 5 6 IN 4 fourth pulse input generic...

Страница 6: ...input blue wire white wire Enery pulse outputs codes 755881 755882 2 3 Remote heating units totaliser output kWh OC type 1 2 Remote cooling units totaliser output kWh OC type These outputs can be conn...

Страница 7: ...ption with optional code 755826 2nd DCW pulse consumption 3rd pulse consumption with optional code 755825 Flow rate Power Flow temperature Return temperature Temperature difference DHW flow rate with...

Страница 8: ...change K V volume change l V N P where N number of pulses P single pulse value per litre Operating specifications 1 In order to protect against spurious measurements or undesired metering the meterin...

Страница 9: ...ass the thread through the hole on the probe and the pocket and twist it E Wind the thread as illustrated in the figure so that once lead sealing is complete the cap cannot be unscrewed without breaki...

Страница 10: ...bob D Pass the thread through the hole on the probe and the pocket and twist it E Wind the thread as illustrated in the figure so that once lead sealing is complete the cap cannot be unscrewed without...

Страница 11: ...SY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY RS485 EASY CONTECA EASY 11 M Bus M Bus Master 230 V ac 755058 M Bus RS 485 slave converter Used to ad...

Страница 12: ...ied out by the user removed Maximum number of users 250 Datalogger specifications Electric supply 24 V dc 10 24 V ac 3 W 2 Ethernet outputs ETH1 PoE ETH2 Working temperature range 0 50 C Mounting 35 m...

Страница 13: ...755881 Acquisition board Terminals 2 3 Heating units 7507 Terminals 2 3 Heating units Terminals 1 2 Cooling units CALEFFI ENERGY kWh 2 6 0 V HEATING UNITS output COOLING UNITS output GND 1 2 3 4 5 6...

Страница 14: ...20030 PULSE MONITOR Pulse logger Electric supply lithium battery 6 digit display with user key Daily data saving Tamper proof seal and sensor Enables acquisition of a pulse output from the heat meter...

Страница 15: ...ues with the aim of providing the exact domestic hot water consumption figure Code 755890 Electronic 8 digit LCD totaliser equipped with cover plate for three slot recessed electric box Lithium batter...

Страница 16: ...ULTRA 7507 series CONTECA EASY ULTRA heat meters in the 7507 series conform to the requirements of directive 2014 32 EU better known as MID acronym for Measuring Instrument Directive Production proce...

Отзывы: