001-0004-819 Rev01
Page 15 of 62
Verify SMC Modem Connectivity
Power on the SMC test board (+12VDC typical), then start HyperTerminal.
Figure 5.2 HyperTerminal screen responses
The
ATI
command prints the cell module product information. If you get an Error or no
communication, verify the modem is connected to the proper COM port and powered on. Refer to
Figure 5.2 for all the AT commands listed below.
Verify the modems Mobile Equipment Identity (MEID) number with the
AT+CGSN
(for Decimal
number) or
AT+GSN
(for Hexadecimal number) command. The MEID number replaces the ESN
(Electronic Serial number).
Verify good signal strength with the
AT+CSQ?
command. A typical reply is +CSQ: 16, 99, using the
mag-mount antenna indoors. The first number is signal strength and ranges from 0 to 31 (the higher
the number, the stronger the signal).
Confirm the phone number currently in the modem with the
AT$SPMDN?
command. If the unit is
not provisioned, the number should be 10 digits beginning with several zeros, i.e. 0000005972.
Exit HyperTerminal before attempting to connect using a Dial-Up-Networking connection.
Содержание SMC-CDMA Series
Страница 51: ...001 0004 819 Rev01 Page 51 of 62 ...
Страница 52: ...001 0004 819 Rev01 Page 52 of 62 ...
Страница 53: ...001 0004 819 Rev01 Page 53 of 62 ...
Страница 54: ...001 0004 819 Rev01 Page 54 of 62 Configuring the Modem ...
Страница 55: ...001 0004 819 Rev01 Page 55 of 62 Create a Dial Up Networking DUN Connection ...
Страница 56: ...001 0004 819 Rev01 Page 56 of 62 ...
Страница 57: ...001 0004 819 Rev01 Page 57 of 62 ...
Страница 58: ...001 0004 819 Rev01 Page 58 of 62 ...
Страница 59: ...001 0004 819 Rev01 Page 59 of 62 ...
Страница 60: ...001 0004 819 Rev01 Page 60 of 62 ...
Страница 61: ...001 0004 819 Rev01 Page 61 of 62 ...